How to change into MANUAL OVERRIDE CONTROL MODE
1. When power is on, the PIR detector enters into the "WARM-UP" periods for about 1 minute, then
automatically changes into AUTO MODE.
2. During AUTO MODE, by switching the ON/OFF main switch twice within 3 seconds and then switching it
on again, the PIR detector will automatically change into MANUAL MODE from AUTO MODE. In MANUAL
MODE, the Lamp(s) will remain ON, not affected by duration time and Lux control level.
3. During MANUAL MODE or AUTO MODE, by switching off the ON/OFF main switch for over 6 seconds and
then on again, the PIR detector will reset to WARM-UP periods. Please note: the periods of "WARM-UP"
maybe shorter than 1 minute.
POWER ON
1
3
MANUAL MODE
Specifications
Detection range: Max. 12 metres at 180°scan
Duration Time adjustment: (10±5) seconds to (4±1) minutes.
Detection circuitry: Passive Infra-Red (PIR)
Power required: 240V AC, 50HZ
Maximum load: 2x13Watt LED.
Weatherproof: IP44