American Standard Portsmouth Champion PRO 213CA Series Інструкція з монтажу Догляд та обслуговування - Сторінка 2

Переглянути онлайн або завантажити pdf Інструкція з монтажу Догляд та обслуговування для Туалети American Standard Portsmouth Champion PRO 213CA Series. American Standard Portsmouth Champion PRO 213CA Series 5 сторінок. 2-piece right height elongated and round front toilets

ROUGHING-IN DIMENSIONS: NOTE: Distance from wall to closet flange centerline must be as listed below: A = 12" (305mm)
Portsmouth
®
Champion
®
PRO 2-piece Toilet 213AA Series Right Height
FINISHED WALL
30-1/4"
(768 mm)
8-7/8"
1"
(226 mm)
(26 mm)
18-1/2"
(470 mm)
3-9/16"
(90 mm)
2-1/16"
(52 mm)
9-3/8"
13-13/16"
(238 mm)
(351 mm)
12"
(305 mm)
Before You Start:
Turn Off Water Supply
Recommended fitting type for
back-to-back installations.
®
Elongated
16-5/8"
(423 mm)
14"
(356 mm)
FINISHED
10-9/16"
FLOOR
(268 mm)
®
Portsmouth
Champion
FINISHED WALL
30-1/4"
(768 mm)
1"
8-7/8"
(26 mm)
(226 mm)
18-1/2"
(470 mm)
3-9/16"
(90 mm)
2-1/16"
(52 mm)
9-3/8"
13-3/16"
(238 mm)
(351 mm)
12"
(305 mm)
If Removing An Existing Toilet
Flush to remove
water from tank;
sponge remaining
water from
bowl before
removing toilet.
Depending upon your plumbing and venting conditions, the flow from the Champion
back-to-back installation may create a vacuum on the system and draw water from the opposing
bowl. The National Standards Plumbing Code prohibits the use of a cross fitting for drainage as
throw over is possible. The code does approve a directional "Y" style fitting with proper venting to
direct the water downward and away from the other toilet.
®
Portsmouth
Champion
FINISHED WALL
(718 mm)
1"
8-7/8"
(26 mm)
(226 mm)
3-9/16"
(90 mm)
2-1/16"
(52 mm)
9-3/8"
(238 mm)
12"
(305 mm)
®
PRO 2-piece Toilet 213CA Series Elongated
FINISHED
FLOOR

BACK-TO-BACK INSTALLATION

- 2 -
®
PRO 2-piece Toilet 213BA Series Right Height
28-1/4"
16-1/2"
(419 mm)
FINISHED
13-7/16"
FLOOR
(341 mm)
16-5/8"
(423 mm)
14"
(356 mm)
10-9/16"
(268 mm)
Clean Flange
Caution: If leaving floor flange
!
open for more than 1-2 hours,
cover flange to prevent escaping
sewer gases.
®
Round Front
16-5/8"
(423mm)
14"
(356 mm)
10-9/16"
(268 mm)
®
PRO in a