American Standard Reliant 250AA104.020 Інструкція з монтажу Догляд та обслуговування - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з монтажу Догляд та обслуговування для Туалети American Standard Reliant 250AA104.020. American Standard Reliant 250AA104.020 12 сторінок. Two-piece toilet
Problem
Possible Cause
Does not
a. Water supply valve closed.
flush
b. Supply line blocked.
c. Flush valve chain too loose or
disconnected.
d. Sand or debris lodged in water control.
Poor or
a. Bowl water level too low.
sluggish
flush
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain
pipe and/or vent.
d. Supply pressure too low.
Toilet
a. Poor supply line connection.
leaks
b. Poor bowl to tank/floor connection.
Toilet does
a. Flapper seal leaking or deformed.
not shut
off
b. Sand or debris lodged in water control.
c. Flush valve chain too tight, holding
flapper open.
Toilet bowl
a. Wax ring not fully compressed.
rocks after
b. Floor not level.
installation
In the United States:
American Standard Brands
1 Centennial Ave
Piscataway, NJ 08854
Attention: Director of Consumer Affairs
For residents of the United States, warranty
information may also be obtained by calling
the following toll free number: (800) 442-1902
www.americanstandard.com
TROUBLESHOOTING GUIDE - See Step 8 For Diagram
Mississauga, Ontario
Toll Free: (800) 387-0369
www.americanstandard.ca
Corrective Action
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all
gaskets and washers. Reassemble.
c. Readjust chain length as required.
d. Shut off water supply. Remove cap and clean as per Fluidmaster
maintenance instructions at:
www.americanstandard-us.com/enews/fluidmasterguide.pdf
a. Check that refill tube is connected to water control and inserted
into overflow tube without being kinked or damaged.
b. Open supply valve fully. Be sure that proper supply tube size
is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
a. Review Step 7 of installation procedure.
b. Review Step 1 through 6 of installation procedure.
a. Clean debris from seal surface. Replace flapper seal as needed.
See web for more info.
b. Shut off water supply. Remove cap and clean as per Fluidmaster
maintenance instructions at:
www.americanstandard-us.com/enews/fluidmasterguide.pdf
c. Readjust chain length as needed.
a. Retighten bowl-to-floor knobs.
b. Use toilet shims and /or place a bead of caulk around the base of
the toilet.
In Canada:
LIXIL Canada ULC
5900 Avebury Rd.
Canada L5R 3M3
- 4 -
In Mexico:
American Standard B&K Mexico
S. de R.L. de C.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
Toll Free: 01-800-839-1200
www.americanstandard.com.mx
7302485-100 10/20