American Standard Colony PRO Series Інструкція з монтажу Посібник з монтажу - Сторінка 3
Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Сантехніка для кухні та ванної кімнати American Standard Colony PRO Series. American Standard Colony PRO Series 20 сторінок. Single control centerset lavatory faucet
Також для American Standard Colony PRO Series: Інструкція з монтажу (4 сторінок)
2
INSTALL POP-UP DRAIN
• Push TAIL PIECE (11) down into TRAP (C) (threaded end up).
• Thread LOCKNUT (5), WASHER (4) and GASKET (3)
(Bevel side up) onto DRAIN BODY (10).
• Apply a bead of PUTTY (D) to underside of FLANGE (2).
• Feed DRAIN BODY (10) up through SINK (A) and thread
the FLANGE (2) fully onto DRAIN BODY (10).
• Tighten LOCKNUT (5) firmly, keeping the pivot rod hole pointed
towards the back of the sink.
• Assemble PIVOT ROD (9) as shown in Figure-2a.
Notice the position of the CONCAVE WASHER (G).
• Insert PIVOT ROD (9) into DRAIN BODY (10) and tighten
PIVOT NUT (F).
• Pull TAIL PIECE (11) up and thread tightly into
DRAIN BODY (10).
• Position EXTENSION ROD (7) onto POP-UP ROD (E) and tighten
THUMBSCREW (6).
• Remove one end of CLIP (8) from PIVOT ROD (9) by squeezing ENDS TOGETHER WHILE SLIDING.
• Insert PIVOT ROD (9) into second or third hole in EXTENSION ROD (7) and reassemble CLIP (8).
• DROP STOPPER (1) into DRAIN BODY (10).
• Adjust stopper height by repositioning EXTENSION ROD (7) and tightening THUMBSCREW (6).
3
CHECK OPERATION OF POP-UP
• Operate LIFT KNOB (1) to verify that
STOPPER (2) opens and closes.
4
MAKE WATER SUPPLY AND WASTE CONNECTIONS
• Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression.
Connect left SUPPLY (1) to Hot (Marked with a Red Band)
and right supply to COLD (2) wall supply.
• Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
• Connect 1-1/4" O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
2
A
3
4
5
10
C
11
1-1/4"
1
2
APPROX. 20"
1
- 2 -
P-2, P-2B - 7075.050
2a
D
G
F
E
6
7
8
F
9
2
BLUE
RED
BAND
BAND
3/8" COMPRESSION
HOT
COLD
M965766 (8/16)