American Standart SELECTRONIC 6055.193 Інструкція з монтажу Посібник з монтажу - Сторінка 8
Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Сантехніка для кухні та ванної кімнати American Standart SELECTRONIC 6055.193. American Standart SELECTRONIC 6055.193 11 сторінок. Proximity infection control faucet
TEST INSTALLED FAUCET
TO ENSURE A LAMINAR WATER FLOW the air must
be slowly purged from the spout. To do so, cover the
SENSOR (1) while slowly opening the water supply
valves. When the water flows as a solid, smooth,
steady stream, uncover the SENSOR (1) and fully
open the water supply valve. Fig. 1.
MAINTENANCE
HAND WASH SENSOR OPERATION;
1
Fig. 1
When the Sensor detects a user, the water
immediately starts to flow. Water flow will stop Two
seconds after user is out of sensor range. The off delay
allows the user to comfortably move his hands without
the flow cycling on to off. As a precaution, a safety
timer will turn off the water, after the sensor has been
blocked for 59 seconds. The water will stay off until the
blockage is removed from the detection zone.
Detection Zone: 2" - 10" (50mm - 250mm)
Default: Set at Factory 6" (150mm)
HOW TO CHANGE SENSOR
2
RANGE; (Factory set at 6") Fig. 2
1. Setting the Detection Zone (Distance):
Remove cover from ENCLOSURE. Disconnect Power
Supply (1), then reconnect. Fig. 2.
2. While the SENSOR CONTROL LED (2) is blinking
slowly, place your hand 1 - 2 in. (30-50mm) in front of
the sensor. Fig. 2a.
3. When the LED stops blinking and stays "ON", move
your hand to the desired position and hold in place until
the LED begins to blink again. Fig. 2a.
4. Once the SENSOR CONTROL LED (2) begins to
blink again, remove your hand from the detection zone.
When the flashing stops, the detection distance is set.
5. Replace ENCLOSURE COVERS (2). Tighten cover
screws firmly.
HOW TO INSTALL AND CHANGE
3
BATTERY; Fig. 3
1. Remove COVER from ENCLOSURE (1). Fig. 3.
2. Remove old BATTERY (2). Install new BATTERY (3)
making sure the terminal side is inserted first and
shape of the battery follows the shape of the
BATTERY HOLDER (4). Fig. 3.
3. Replace ENCLOSURE COVER. Tighten cover
screws firmly. Fig. 3.
Fig 1
Fig. 2
1
Fig. 2a
1" - 2" (30mm - 50mm
2
BLINKING LED
Fig.3
7
1
UP TO 10" (250mm)
2
BLINKING
LED
1
3
6
2
4
M 9 6 5 119 R E V. 1. 3