Door-Gard 232iLM Інструкції з встановлення та програмування
Переглянути онлайн або завантажити pdf Інструкції з встановлення та програмування для Домофонна система Door-Gard 232iLM. Door-Gard 232iLM 8 сторінок. Keypad
232iLM Keypad Installation & Programming
Specifi cations
Case Dimensions:
6-1/2" L x 1-3/4" W x 1-1/8" D
Electrical:
Voltage: 5-12 VDC (keypad)
12-24 VAC/DC (controller)
Current (max): 120 mA
Relay Contacts:
Main Relay (controller): 2 Amps
Aux Relays (controller): 1 Amp
Bell Relay:
Form A; 1 Amp @ 30 VDC;
500 mA @ 125 VAC
Environmental:
-20º F to 130° F
Description:
The 232iLM Access Control unit consists of two pieces:
an SSWiLM keypad front end and a 232 Access Control
Module. The Door ♦ G ard Series SSWiLM keypad
combines elegant looks with a mullion mount design in
a rugged, vandal resistant case, which you can use for
almost any application. The SSWiLM has hardened backlit
keys designed to perform in medium to high traffi c areas
and in rough duty environments. The electronics are also
conformal coated, which makes the keypad suitable for
indoor or outdoor applications.
Basic Operation:
To gain access through the door enter your code
(1-6 digits) followed by the ✱ key on the keypad.
Packing List:
(1) SSWiLM Keypad
(1) 232 Access Control Module
(1) Eight-Conductor Wire Harness
(4) Three-Conductor Wire Harness
(1) Controller Hardware Pack
(1) Mullion Hardware Pack
(1) 5/64" Allen Wrench
(1) Anti-Oxidant Grease Pack
(1) Installation/Programming Manual
(1) Self-Contained Access Control Programming Guide
6-050800 X2
Installation & Programming Instructions
Note: This product is designed to be installed and serviced
Features
●
Vandal Resistant Case
●
Sealed for Indoor or Outdoor Applications
●
LED's for Relay Status Indication
●
Bell Output
●
Surface Mount
●
Illuminated Hardened Keys
●
Rated for Greater than One Million Key Cycles
Applications
●
Low to Medium/Heavy Traffi c Areas
●
Rough Service Environments
●
Mullion Frame Mounting
●
Dimly Lit Areas
Wire Harness Confi guration:
Pin
Wire Color
1
Red
2
Black
3
White/Black
4
White/Yellow
5
Blue
6
Brown
7
White
8
White
Wiring Requirements:
18 AWG – 1000 Ft.
20 AWG – 500 Ft.
22 AWG – 250 Ft
232iLM Keypad
by security and lock industry professionals.
Signal Name
Power (+)
Power (-)
Data 0
Data 1
Not Used
Not Used
Bell Relay Contact (A)
Bell Relay Contact (B)
1