General Operating Conditions 
The R‐Series Dia‐Vac® explosion proof motors utilized by the R‐Series single and double head pumps are 
1/6 HP, 115V/230V, 50/60Hz single phase and are UL and CSA listed Class I, Division I, Group B, C and D, 
and Class II, Group F and G. For Quad and Eight head Dia‐Vac® pumps, the motor may range from 1/2 ‐ 1 
HP, and are UL and CSA listed Class I, Division I, Group C, and D, and Class II, Group F, and G.  
 
Dia‐Vac® Pumps are intended for use with gases only, do not use this product for liquids. The elevated 
and  extended  pumps  are  for  use  in  hazardous  areas  where  heated  heads  cannot  be  used  to  prevent 
condensation buildup in the pump. These pumps are designed to have head or heads mounted in a heated 
enclosure to prevent condensation of vapors within the pump head. The plate of either of these pumps 
can hold the entire weight of the pump. 
 
The Dia‐Vac® Pump normally runs at 130 to 150 °F. It is not an indication of trouble if the outer surfaces 
of the pump or motor are hot to the touch. 
 
The Dia‐Vac® Pump normally runs quietly, especially when both pressure and vacuum ports are connected 
into  a  closed  system.  An  obvious  knock  or  rattle  could  indicate  a  problem.  Check  through 
"Troubleshooting" with particular attention to the tightness of all screw fasteners. 
 
Ambient  temperature  of  this  pump  should  not  exceed  60°C/140°F.  The  pump  must  have  adequate 
ventilation and/or cooling to run properly.  
Safety 
Before running the pump, ensure that it is properly rated for the environment in which it is located. The 
Standard Dia‐Vac® explosion proof motors utilized by the standard single and double head pumps are UL 
and CSA listed Class I, Division I, Group B, C, and D, and Class II, Group F and G.  
 
All  system  components  connected  to  the  Dia‐Vac®  Pump  must  be  capable  of  handling  the  maximum 
pressure of the pump.  
 
Ensure  that  safety  regulations  are  observed  when  connecting  the  pump  to  the  electric  supply.  The 
connections  are  to  be  made  in  such  a  way  that  contact  by  any  object  or  person  with  a  live  wire  is 
impossible. The connections must be protected so no arcing or sparks are possible. The supply voltage 
must not vary more than ± 10% of the voltage shown on the motor plate. 
 
All proper precautions for the controlled vapor must be observed, and followed. Proper wetted materials 
for handling corrosive, hot, and/or reactive gases must be used. 
 
This Dia‐Vac® Pump is thermally protected; when the temperature of the pump exceeds the maximum 
operating temperature, pump operation will be interrupted by the thermal switch. The pump will restart 
automatically once it cools down. Be sure to take necessary precautions to avoid injury during restart.  
 
Disassembly of the pump or motor beyond what is detailed in the servicing section below may result in 
the loss of the pump's hazardous area certification and is highly discouraged.