QUICKSTART ADJUSTMENTS AND PROGRAMMING OPTIONS FOR WIRELESS BOARDS GUIDELINES
For COMPLETE programming and adjustment instructions, please refer to the instruction sheets included with the wireless kits,
IMPORTANT
8
All tracker expansion boards
CH
Wireless Layout and Start-Up Guide and the HARDwired Installation/Owner's manual (P/N 2358-065).
MUST be set to SAME channel
number as wireless baseboard.
Wireless Baseboard
8
IMPORTANT
NET
All tracker expansion boards
ID
MUST be set to SAME NET ID
RF RANGE
number as wireless baseboard.
Set to max (full clockwise). This may
need to be changed when using a
RESET Button - Press to reboot board.
repeater. See Repeater instruction
sheet and Wireless Start-Up guide for
ON - Only accepts card codes
PAIRED
more information.
from PAIRED tracker boards.
ON
8
RF RANGE
CH
RESET
OFF - Normal Setting - Allows
OFF
card codes from paired or
PAIRED
8
NET
unpaired tracker boards.
ON
ID
OFF
RCVD
SYNC LOST
Yellow - RECD
SYNC REVD
DISPLAY
ALLOW
Green - ALLOW
OFF/ON
Display Jumper
DENY
HEARTBEAT
Red - DENY
STATUS
Not used - STATUS
Red - No Signal - SYNC LOST
SYNC REVD:
Blinking Blue - Searching
Steady Green - connected.
HEARTBEAT:
Blinking Green - Normal
Baseboard LED Display
When board is powered up OR PROG
PROG
PAIR
Button is pressed, LED display (display
jumper ON) shows RF RANGE adjustment
RF
setting on board for a few seconds
STAT STRENGTH
RF STAT
(number has a decimal point in
ON - Connection to at least 1 remote
the lower right of the LED
Blinking - No connection
Display), then LED display will
RED - Not paired
automatically change to RF STRENGTH
Green - Paired STRENGTH
number continuously (NO decimal point
displayed for RF strength number). This
Green - Good
number is the ACTUAL RF signal loss
Amber - Marginal
being sent/received by the board.
Red - Poor
Program Button - Press after adjustment is made to RF RANGE,
RF ID or RF CHANNEL before changes will take effect.
PAIR Button - Press and hold 3 sec. to PAIR with all wireless tracker boards.
Press to display RF RANGE and RF STRENGTH on LED Display.
Wireless Tracker Expansion RF Board Adjustments
RF Range
Program Button:
Press after adjustment has been made to
RF RANGE, RF ID or RF CH before
changes will take effect.
Set to max (full clockwise). This may
Press and hold for 3 sec. to PAIR to
need to be changed when using a
wireless baseboard, may take up to 20 sec.
(RF SECURE LED Paired - steady GREEN).
repeater. See Repeater instruction sheet
and Wireless Start-Up guide for more
Press and hold again for 3 sec. to UNPAIR
information.
from wireless baseboard if necessary
(RF SECURE LED Unpaired - steady RED).
Basic Programming Sequence on EACH Wireless Tracker Expansion Board
Follow these basic steps to perform desired programming, See programming options table for PROGRAM STEPS.
1. Press
arrow buttons or ENT button to ACTIVATE LED display.
2. Press
arrow buttons again to CHOOSE desired PROGRAM STEP.
3. Press ENT button to ENTER desired PROGRAM STEP. (LED display number will blink after ENT button has been pressed).
4. Press
arrow buttons to choose SELECTION NUMBER for desired function of program step.
5. Press ENT button to program SELECTION NUMBER for desired function of program step. (Function has now been programmed into board).
6. Press ENT button again to exit programming OR after 10 seconds, board will automatically exit programming.
Note: Repeat these steps for all other desired programming functions. Each tracker expansion board will have to be INDIVIDUALLY programmed
with desired functions. After all tracker expansion boards have been programmed.....
Manage the Complete Access Control System from Your PC
Refer to the DKS Remote
Account Manager Software
to program and manage the
complete system.
Your PC connected to the access control system. Either IM Server OR TCP/IP OR RS-232 OR
Modem to Modem Connection. See PC Programmable Telephone Entry and Access Control
Systems Installation/Owner's manual for more information about connection options.
DO NOT connect HARDwired tracker expansion boards to wiegand 1 (terminals 11-14)
if WIRELESS boards will be using wiegand 1).
Antenna is REQUIRED.
DOORKING
2363-010
HARDwired Card Reader or Relay 1/Wiegand 1
14
connection ONLY. DO NOT connect HARDwired tracker
13
12
expansion boards or card reader to wiegand 1
11
(terminals 11-14) if WIRELESS boards will be using
6
wiegand 1).
See instruction sheet with wireless baseboard kit
5
for more information.
4
3
2
1
Power
REQUIRED
Transformer
Connect Existing
Auxiliary Terminal
Access Control
18 AWG 100 ft max
System Power
16 AWG 200 ft max
DOORKING
2361-010
RLY 1 RLY 2
BOARD ADDRESS
ON
Board addresses MUST be set for
1
each board used.
See other side for more information.
0
1
2
4-Pin Terminal:
3
RLY 2: Must connect to access control
4
system's Relay 2 for wireless tracker
expansion board addresses 3-10.
5
Access control system's relay 2 jumper
6
Data 0
MUST be set to NO or NC.
7
Data 1
RLY 1: Must connect to access control system's
Com
8
Relay 1 for wireless tracker expansion board
12 VDC
9
addresses 11-18. See instruction sheet with
10
wireless baseboard kit for more information.
RF RANGE
11
12
13
14
Channel and ID
15
Door Contact Switch
IMPORTANT
16
8
All tracker expansion boards
17
RF
MUST be set to SAME channel
18
CH
Request to Exit
number as wireless baseboard.
19
20
8
IMPORTANT
Card Reader
LED/Beeper
RF
All tracker expansion boards
Control
ID
MUST be set to SAME NET ID
number as wireless baseboard.
LED Display
TELEPHONE ENTRY SYSTEM
OPERATING INSTRUCTIONS
1.
Use "A to Z" Buttons to Locate
Name and Code Number on Display.
Names are In Alphabetical Order.
2.
T o Call, Enter Code Number on
Keypad or Press "Call" Button. If
Line is Busy, Press "#" or "Call" to
Hang Up. Try Again.
3.
E nter on Open Display and Tone.
Programming Options on EACH Wireless Tracker Expansion Board
Program
Step
1
Wireless Tracker
Expansion Board
2
3
RF SECURE:
UNPAIRED MODE:
4
Steady Red – Board is communicating with unpaired wireless baseboard.
Blinking Red – Board is NOT communicating with unpaired wireless baseboard.
5
PAIRED MODE:
Steady Green - Board is communicating with paired wireless baseboard.
Blinking Green - Board is NOT communicating with paired wireless baseboard.
6
RF DATA – (Green) Reply from baseboard.
7
RF STATUS – (Green) Not used.
CODE SENT – (Yellow) Card code is sent to baseboard.
8
CODE GOOD – (Green) Access granted.
CODE BAD – (Red) Access denied or card code not in database.
9
Antenna is REQUIRED.
RF
OUTPUT
ALARM
AUX
2358-010
SECURE
RF
RF
CODE
CODE
CODE
RELAY
RELAY
RELAY
DATA
STATUS
SENT
GOOD
BAD
NC
NC
NC
Relay jumpers MUST be
NO
NO
NO
10
set for each relay used.
21
Aux Relay
11
22
23
Alarm Relay
24
25
Output Relay
26
27
12
28
RF SYNC:
RF
29
Slowly Blinking Blue -
SYNC
13
Sync to baseboard.
30
RF
14
LOST
31
RF ID
RF CH
RF
STRENGTH
PROGRAM
32
Ground - REQUIRED
4
4
POWER
33
34
1489-010
REQUIRED
RESET
15
Power
Transformer
ENT
18 AWG 100 ft max
16 AWG 200 ft max
RF STRENGTH
Green - Good
Amber - Marginal
Red - Poor
RESET Button -
Press to reboot board.
IMPORTANT Display Decimal Point Note
Door Operation Note:
PROPER Condition:
system OR request to exit device HAS
activated the OUTPUT RELAY on the
When decimal point is
tracker expansion board and the door
displayed: Indicates you are
contact switch is CLOSED (Door is
SELECTING a program step.
OPEN). This indicates that the door has
been PROPERLY OPENED.
16
FORCED Condition:
When decimal point is NOT
system OR request to exit device has
displayed: Indicates you are
NOT activated the OUTPUT RELAY on
the tracker expansion board and the
IN a program step.
door contact switch is CLOSED (Door is
OPEN). This indicates that the door has
been FORCED OPENED.
17
18
19
20
SP
1
ABC
2
DEF
3
GHI
4
JKL
5
MNO
6
21
PQRS
TUV
WXYZ
7
8
9
0
OPER
HOLD TO SCAN
A
22
Z
CALL
Copyright 2014 DoorKing, Inc. All rights reserved.
Selection
Description
Options
Number
Sets Strike Time for output relay (term 25 & 26)
Door Strike Timer
00 - 99
00
0.25 second strike time
01 - 99
Strike time in 1-second increments
Set Strike Time for RX (Request to Exit) of output relay (input at term 18)
Free Exit Timer, Strike Time
00 - 99
00
0.25 second Egress Strike time
Egress Strike time in 1-second increments
01 - 99
Timer starts when valid access has been granted.
Door Ajar Timer
00 - 99
00
1 second Door Ajar Timer
01 - 99
Timer set in 5-second increments: 01 = 5 seconds, 10 = 50 seconds
Timer setting for Aux Relay activation in 5-second increments
00
1 second Door Ajar Timer
Aux Relay Timer
00 - 99
01 - 99
Timer set in 5-second increments: 01 = 5 seconds, 10 = 50 seconds
Set Strike Time for RX (Request to Exit) of Aux relay (ONLY available if Dual Door Mode step 12 is ON)
00
0.25 second Egress Strike time
Free Exit Timer, Aux Relay
00 - 99
01 - 99
Egress Strike time in 1-second increments
Set RX (Request to Exit) function. Activate Output Relay or do not Activate Output Relay
Free Exit, No Strike
0 or 1
0
Do Not Activate Output Relay or Reader Beeper/LED when RX input is received
Activate Output Relay and Reader Beeper/LED for Free Exit Strike Time when RX received
1
Not Used
Sets type of Door Switch contacts
0
N.O. contact from door switch with Door Closed (Circuit Open - CO)
Door Contact Switch Logic
0 or 1
1
N.C. contact from door switch with Door Closed (Circuit Close - CC)
Turns on Auto Relock function (not available if Dual Door Mode, step 12 is ON)
Auto Relock
0 or 1
0
Output Relay is activated for Strike Time
1
Door Contact Switch required. If door returns to closed position during Strike Time
door will "relock" after 1 second, even if strike time has not expired.
Sets how BEEPER or LED will function during Hold Open
0
When Hold Open occurs, Beeper or LED is active only during Strike Timer
Beeper / LED Hold Open
0 or 1
1
When Hold Open occurs, Beeper or LED will remain active during Hold Open
Sets how Aux & Alarm Relay responds during Hold Open or Hold Egress situation
0
No Aux Relay functions. Alarm will be in "Reset". If Alarm Relay is set for "integral" mode, Alarm relay will not activate. If
Hold Open or Hold Egress functions
0 or 1
Alarm Relay set for "Bypass" mode, Alarm Relay will activate for Hold Open period or Extended Egress Hold.
1
Aux Relay will function for all settings. If Alarm Relay is set for "integral" mode, Alarm relay will not activate. If Alarm Relay set
for "Bypass" mode, Alarm Relay will activate for Hold Open period or Extended Egress Hold.
Sets Tracker to function as 2 Access Points (2 tracker addresses)
0
Disabled, Tracker functions as single access point
Dual Mode: Tracker functions as set board address and next sequential address
1
Card Read will be sent to controller as set board address, access is granted or denied
Dual Door Mode
0 or 1
Card then sent as set address +1, access granted or denied. Aux Relay becomes 2nd output relay. All other Aux Relay functions
disabled. Door Contact switch becomes RX (Request to Exit) for 2nd address.
Not Used
Not Used
Sets function for Aux Relay
0
Aux Relay Disabled
1
No Door Ajar Timer: Requires Door Contact Switch. Aux Relay activates when Door Not Closed.
2
No Door Ajar Timer, Pulse: Requires Door Contact Switch. Aux Relay "pulses" when Door Not Closed.
3
Door Ajar Timer: Requires Door Contact Switch. When door opens, start Door Ajar Timer. When timer expires Aux Relay
activates for Aux Relay timer or until door closes, whichever occurs first.
4
Door Ajar Timer, Pulse: Requires Door Contact Switch. When door opens, start Door Ajar Timer. When timer expires Aux Relay
Pulses for Aux Relay timer or until door closes, whichever occurs first.
5
Door Ajar, Pulse warning the ON: Requires Door Contact Switch. When door opens, Pulse Aux Relay and start Door Ajar Timer.
When timer expires Aux Relay ON for Aux Relay timer or until door closes, whichever occurs first.
Aux Relay Functions
0 - 12
6
Door opens for any reason, Start Door Ajar timer and pulse Aux Relay. When Door Ajar timer expires, start Aux Timer and
continue Pulsing Aux Relay.
When Door Closes or both timers expire, turn off Aux Relay
7
Aux Relay as 2nd Alarm Relay. Aux Relay will mirror Alarm Relay functions.
Aux Relay as 2nd Alarm Relay, PULSE. Aux relay will Pulse during any Alarm Relay activation.
8
9
Good Card: Aux Relay will activate for Aux Relay timer for any Access Granted Card
10
Any Card: Aux Relay will activate for Aux Relay Timer when any card has been presented.
11
Bad Card: Aux Relay will activate for Aux Relay timer when a card has been denied
12
Warn before Hold Open or Release of Hold Open: Aux relay will activate for Aux Relay timer when scheduled Hold Open begins
or ends. Output Relay will be delayed until Aux Timer expires. DO NOT set Aux Timer above 60 seconds in this mode.
Alarm Relay Functions
Sets function for Alarm Relay
0
Aux Relay Disabled
Bypass Mode: Alarm Relay provides "Bypass" to Alarm Door Switch. With proper door input (access or egress) activate Alarm
The access control
1
Relay, start Strike timer and Door Ajar timer. When Door Ajar timer expires, deactivate Alarm Relay.
If second Door Contact Switch is provided, generate transaction for Door Ajar and Door Closed following Door Forced condition.
Also generate transaction for Door Forced condition.
Integral Mode, Door Ajar Timer: Door Contact Switch connected to Tracker, Alarm Relay provides connection directly to Alarm
2
System. When door is opened for any reason, start Door Ajar timer. When Door Ajar timer expires and Door is still OPEN,
activate Alarm Relay. Reset when door closes.
Send Door Ajar and Door Close transactions.
0 - 4
The access control
Integral Mode, Proper and Forced condition: Door Contact Switch connected to Tracker, Alarm Relay provides connection
directly to Alarm System. With proper door input (access or egress) start Strike timer and Door Ajar timer. When Door Ajar
3
timer expires and Door is still OPEN, activate Alarm Relay. Reset when door closes.
If door is opened without proper condition, activate alarm relay. When door closes deactivate Alarm Relay. Send Door Ajar,
Door Close and Door Forced transactions.
4
Gate Alarm Function: Alarm Relay will activate for 1 second when tracker board receives a "Gate Forced" or "Gate Obstructed"
transaction from the operator control board.
Not Used
Not Used
5
Sets all parameters to Factory Default
Reset to Factory Defaults
5
View RF POT Setting
Adjustable Setting
Sets maximum amount of allowable signal strength loss
Displays on LED
Displays current signal loss between Base and Tracker.
View RF Signal Loss
Sets Wireless Tracker to act as Repeater
ONLY USE AS DIRECTED BY DOORKING TECH SUPPORT 0=Repeater Mode OFF 1=Repeater Mode ON
Card Code Forwarding
0 or 1
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
Rev-E 1-13-14
Factory
Function
Default
01 - 1 second
01 - 1 second
12 - 60 secs
12 - 60 secs
01 - 1 second
1 - Activate
0 - N.O.
0 - Disabled
0
0 - No relay
functions
0 - Disabled
0 - Disabled
0 - Disabled
0 - Off
2358-067-E-10-14