4. STARTING UP
1. Remove the cover of the unit to begin the start up. Unscrew the 6 screws that
affix the hinge to the cover- not those that affix the hinge to the unit- before
lifting it.
CONSULT THE MANUAL FOR THE FILTER
2. Open the filter and fill it halfway with water. Protect the diffuser in the interior
of the filter so sand does not get into it.
3. Fill the filter with the appropriate quantity (indicated on the specifications
label, or up to 2/3 of the total filter height) of silex sand with a grain size of 0.4 -
0.8
4. Clean the remnants of silex from the mouth, cover and gasket housing, and
close the filter. For more information, please consult the manual for the filter.
If the unit is below the water level, you will only need to open the input and
output valves and the air vent until the filter and the pump are full of water.
5. Put the valves in the following positions:
-SKIMMER OPEN
-DRAIN INPUT OPEN
-POOL CLEANER OPEN
-RETURN OPEN
-SELECTOR VALVE CLEAN
6. Start up the pump and clean the filter.
Run the cleaning until you see that the water is clean and clear in the window on
the selector valve.
7. Turn off the pump.
Position the selector valve to rinse and run the pump for about 15 seconds.
Stop the pump again and put the selector valve on filter.
8. Close the selector valve of the pool cleaner.
9. Connect the pump.
Note: Any changing of the position of the selector valve must be done with the
puma stopped. Otherwise, the filter or the installation could be damaged.
Replace the cover of the unit, affixing the rear part with the corresponding
screws.
- IT IS RECOMMENDED THAT YOU USE A LOCK OR PADLOCK SO
THAT CHILDREN OR OTHER UNAUTHORISED PERSONS CANNOT
ACCESS THE INTERIOR OF THE UNIT
PROGRAMMING THE FILTER. See instructions for the programmer in the interior
of the control panel.
ONLY FOR MODELS WITH AN ELECTRICAL CONTROL PANEL
9
10
ATTENTION