Переглянути онлайн або завантажити pdf Інструкція з монтажу для Сантехнічний виріб Akw GW90. Akw GW90 4 сторінки. Shower waste
Suitable for wooden and solid floor installations. Use these in accordance with the shower tray instructions.
A
Order: 01905 823 299
|
Installation Instructions
Installation Instructions
(1) As a "dry run", first place
the tray into the desired
location either into wooden
or solid floors. Determine
the position, the depth and
the clearance required for
the waste with at least a 1
in 40 fall from the waste to
the outlet pipe. Ensure there
is sufficient support around
the waste area, see separate
tray instructions.
(2) Before fitting the waste,
place the nut onto the waste
pipe outlet, followed by the
backing ring and the seal.
Insert waste pipe into the
waste body and tighten the
nut. Check that the pipe
connection is correctly
assembled, sealed and
watertight by pouring some
water through it. Ensure that
the rubber clamping seal
(A) is positioned into the
recessed section on the top
of the waste body before
connecting to the tray.
(3-4) Apply flexible adhesive
to the tray and ensure that
A
the tray is level. Lower the
tray into position either into
or onto wooden or concrete
floors and then re-align with
the waste body.
(5-6) Ensure the clamping
ring (B) is screwed correctly
to the waste body and is
aligned with the tray. Do not
over tighten but ensure a
tight seal.
(7) Lower the waste trap
body into waste main body
and ensure a tight seal is
achieved.
(8) Fit the cover ensuring
correct location and it is
flush with the tray. Protect
the trap from debris during
installation.