Doran 2200 Series Посібник оператора - Сторінка 11

Переглянути онлайн або завантажити pdf Посібник оператора для Сенсорна панель Doran 2200 Series. Doran 2200 Series 15 сторінок.

Doran 2200 Series Посібник оператора

Password Protected Setpoint and Preact Values

If the password protection is activated, the display will display pass when the SET
POINT button is pressed. Enter the password and press ENTER. Press SET POINT to
change or review setpoints or press and hold SET POINT to edit or review preacts.
After reviewing the setpoints or preacts, the password will be required the next time the
SET POINT button is pressed.

Display Setpoint Values

Press SET POINT to display the current setpoint values. The last viewed or edited
setpoint will be displayed. Press UNITS and PRINT to scroll through the eight available
setpoints. The annunciators below the main display indicate the current setpoint. Press
SET POINT to exit this mode. The display will read abort to indicate no changes were
made to the setpoint values.
Press ZERO to momentarily display the current parameter settings and output logic for
that individual setpoint.

Change Setpoint Values

Press SET POINT to enter the setpoint edit mode. The last viewed or edited setpoint
will be displayed. Press UNITS and PRINT to scroll through the eight available
setpoints. The annunciators below the main display indicate the current setpoint.
To change the setpoint value, enter the setpoint value using the numeric keypad. Press
ENTER to accept the change and return to the weigh mode or press UNITS or PRINT to
save and edit other setpoints. Press SET POINT to exit this mode.
The display will read abort to indicate no changes were made to the setpoint values or
the display will read Saved to indicate the setpoint value is saved.

Barcode Entry of Setpoint Values

Press SET POINT to enter the Setpoint edit mode. The display will momentarily show
SEtPt, then flash the current setpoint weight. Press UNITS or PRINT to scroll to the
desired setpoint number. The annunciators below the main display indicate which
setpoint is currently displayed.
Using Doran's optional barcode scanner, scan the desired barcode. The display will
read SAVEd to indicate the scanned setpoint weight is saved. The display will flash the
new setpoint weight scanned from the barcode. No special serial commands are needed
prior to the weight data in barcode value. The barcode value must not exceed the
indicator's count by resolution and can not be greater than the capacity. The barcode
value can be read into each of the eight available setpoints. To exit the edit mode press
the SET POINT button.