Wiring:
If you want to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal "L / +" of INPUT, and connect the negative pole of DC power supply to terminal "N / -" of
INPUT.
2) Connect terminal C to the positive pole of DC power supply, connect terminal B to the positive pole of DC lamp, and connect the negative pole of
DC lamp to the negative pole of DC power supply.
If you want to control an AC 220V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal "L / +" of INPUT, and connect the negative pole of DC power supply to terminal "N / -" of
INPUT.
2) Connect terminal C to the live wire of AC power supply, connect terminal B to one side of AC lamp, and connect another side of AC lamp to the
neutral wire of AC power supply.
Setting different control modes:
Setting different control modes: (We have set the receiver in toggle mode before delivery, if you want to use other modes, do as following operation.)
1) Learning Toggle control mode (with the transmitter CV-8): When the receiver is in the status of LEARNING, press button 1 of the remote control to
learn receiver 1, press button 5 to learn receiver 2.
Control mode Toggle (remote button 1, 2, 3 and 4 are for receiver 1; remote button 5, 6, 7 and 8 are for receiver 2): Press -> On; Press again -> Off.
Press button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Press button 1 again: Turn off relay 1 of receiver 1 (disconnect B and C, connect A and B), the lamp 1 is off.
...
Press button 4: Turn on relay 4 of receiver 1 (connect B and C, disconnect A and B), the lamp 4 is on.
Press button 4 again: Turn off relay 4 of receiver 1 (disconnect B and C, connect A and B), the lamp 4 is off.
Press button 5: Turn on relay 1 of receiver 2 (connect B and C, disconnect A and B), the lamp 5 is on.
Press button 5 again: Turn off relay 1 of receiver 2 (disconnect B and C, connect A and B), the lamp 5 is off.
...
Press button 8: Turn on relay 4 of receiver 2 (connect B and C, disconnect A and B), the lamp 8 is on.
Press button 8 again: Turn off relay 4 of receiver 2 (disconnect B and C, connect A and B), the lamp 8 is off.
2) Learning Momentary control mode (with the transmitter CV-8): When the receiver is in the status of LEARNING, press button 2 of the remote
control to learn receiver 1, press button 6 to learn receiver 2.
Control mode Momentary (remote button 1, 2, 3 and 4 are for receiver 1; remote button 5, 6, 7 and 8 are for receiver 2): Press and hold -> On;
Release -> Off.
Press and hold button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Release button 1: Turn off relay 1 of receiver 1 (disconnect B and C, connect A and B), the lamp 1 is off.
...
Press and hold button 4: Turn on relay 4 of receiver 1 (connect B and C, disconnect A and B) the lamp 4 is on.
Release button 4: Turn off relay 4 of receiver 1 (disconnect B and C, connect A and B), the lamp 4 is off.
Press and hold button 5: Turn on relay 1 of receiver 2 (connect B and C, disconnect A and B), the lamp 5 is on.
Release button 5: Turn off relay 1 of receiver 2 (disconnect B and C, connect A and B), the lamp 5 is off.
...
Press and hold button 8: Turn on relay 4 of receiver 2 (connect B and C, disconnect A and B), the lamp 8 is on.
Release button 8: Turn off relay 4 of receiver 2 (disconnect B and C, connect A and B), the lamp 8 is off.
3) Learning Latched control mode (with the transmitter CV-8): When the receiver is in the status of LEARNING, press button 3 of the remote control to
learn receiver 1, press button 7 to learn receiver 2.
Control mode Latched (remote button 1, 2, 3 and 4 are for receiver 1; remote button 5, 6, 7 and 8 are for receiver 2): Press -> On, other relays Off;
Press other button -> Off.
Press button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Turn off other relay (disconnect B and C, connect A and B), the lamp 2, 3 and 4 are off.
...
Press button 4: Turn on relay 4 of receiver 1 (connect B and C, disconnect A and B), the lamp 4 is on.
Turn off other relay (disconnect B and C, connect A and B), the lamp 1, 2 and 3 are off.
Press button 5: Turn on relay 1 of receiver 2 (connect B and C, disconnect A and B), the lamp 5 is on.
Turn off other relay (disconnect B and C, connect A and B), the lamp 6, 7 and 8 are off.
...
Press button 8: Turn on relay 4 of receiver 2 (connect B and C, disconnect A and B), the lamp 8 is on.
Turn off other relay (disconnect B and C, connect A and B), the lamp 5, 6 and 7 are off.
4) Learning Momentary (Channel 1~2 of receiver 1, 2 and 3) + Toggle (3, 4 channel of receiver 1, 2 and 3) control mode (with the transmitter CV-8):
When the receiver is in the status of LEARNING, press button 4 of the remote control to learn receiver 1, press button 8 to learn receiver 2, press
button 12 to learn receiver 3.