Astromi.ch MGPBox Посібник - Сторінка 17

Переглянути онлайн або завантажити pdf Посібник для Блок управління Astromi.ch MGPBox. Astromi.ch MGPBox 20 сторінок.

Additionally, MGPBox can also send information about calibration values stored in the
EEPROM.
Standard Firmware:
$PCAL,P,0,T,0,H,0,MM,1,MG,0*69<cr><lf>
10Micron specific Firmware:
$PCAL,P,0,T,0,H,0,UR,0,UT,0,CUT,0*16<cr><lf>
$
P
CAL
P
20
T
50
H
-10
MM / UR
1
MG / UT
0
CUT
0
*69 / *16E

Setting, resetting, receiving Calibration data and other commands

In order to set, reset or query calibration data from the MGPBox, similar formatted sentences
can be sent to the device:

Setting pressure calibration

:calp,50*
:calp
50
*

Setting temperature calibration

:calt,22*
:calt
22
*
Start of sentence
Proprietary sentence
Calibration data
Sensor type, pressure
Calibration value multiplied by 10, e.g. 2.0
hPa
Sensor type, temperature
Calibration value multiplied by 10, e.g. 5.0 °C
Sensory type, humidity
Calibration value multiplied by 10, e.g.
-1.0 %RH
MM: Send Meteo-Data to mount
UR: Update mount's refraction data
Yes (0 = No)
MG: Send GPS-Data to mount
UT: Initially synchronize mount's time
Disabled (1 = Enabled)
Continuously synchronize mount's time
Disabled (1 = Enabled)
Checksum
Set calibration value for pressure
Calibration value multiplied by 10, e.g. 5.0 °C
End of message indicator
Set calibration value for temperature
Calibration value multiplied by 10, e.g. 2.2
hPa
End of message indicator
Page 17
Version 1.1