5 BIOS Setup

The BIOS needs now to be checked to be sure it still has the proper boot order. Follow
the steps below:
Start with the unit powered OFF.
Power ON the unit.
Press the "Delete" key on the keyboard when the SuperMicro load (splash)
screen appears, in order to enter into the BIOS configuration.
In "Main" tab change the Time and Date to "GMT" time and date according to a
GMT clock set to GMT +/- 1 minute.
Set the following:
Native Mode Operation
SATA RAID Enable
SATA AHCI Enable
SATA AHCI Legacy Enable
Go in "Advanced" menu, choose "Boot Features" and make sure that the
following is set:
Only USB Port #6 cab boot
Power Loss Control
Still within the "Advanced" menu, go to "Hardware Monitor" and make sure that
the following is set:
Fan Speed Control Mode
In the "Boot" menu:
Press the key "3" to load Doremi boot order. You should read:
Boot Priority Order:
1. USB HDD: Intel Value SSD - (USB 1.1)
Troubleshooting tips:
If the USB HDD: Intel Value SSD – (USB 1.1) is not detected in "Boot
Priority Order": power the unit off, reconnect flash or check the cable and
then power on the unit to check that it is now detected.
After Boot Priority is correctly set, press F10 and confirm by pressing <enter>.
When completed, check mark the tag attached to the DCP-2000 at the "BIOS
Configuration" position, indicating that this configuration was performed and successful.
The SDD flash replacement procedure is now completed.
Please contact our Technical Support department at 1-818-562-1101 or email
[email protected] if you have any questions or are in need of assistance.
Thank you.
D2K.DP.000804.DRM
Page 10
Doremi Cinema LLC Confidential
[Serial ATA]
[Disabled]
[Enabled]
[Disabled]
[Enabled]
[Last State]
[3-pin Server]