Canon 7215 - LV XGA LCD Projector Специфікація - Сторінка 47
Переглянути онлайн або завантажити pdf Специфікація для Проектор Canon 7215 - LV XGA LCD Projector. Canon 7215 - LV XGA LCD Projector 47 сторінок. Mounting hanger for low ceilings
Також для Canon 7215 - LV XGA LCD Projector: Специфікація (22 сторінок), Посібник зі збирання та встановлення (японською мовою) (8 сторінок)
EXPAND SERIAL COMMAD FUNCTIONAL SPECIFICATION for LV-5210/7215/7210
9.12.4 CR_PTIMERCOMMAND
COMMAND
"CR_PTIMER" [CR]
Details
Get Presentation Timer status
Acceptable
Response
Unacceptable
9.12.5 CR_TEMPWARNCOMMAND
COMMAND
"CR_TEMPWARN" [CR]
Get if the sensors are exceeding or approaching critical temperature. When
Details
some sensors are installed inside the projector, get each sensor's
temperature.
Acceptable
Response
Unacceptable
9.12.6 CR_TEMPFAILCOMMAND
COMMAND
"CR_TEMPFAIL" [CR]
Get the temperature inside a projector.
Details
When some temperature sensors are installed in the projector, it is possible
to know the temperature all at once.
Acceptable
Response
Unacceptable
"000_%a" [CR]
"ON"------- Presentation timer is active
%a
"STOP"--- Presentation timer is pause
"OFF"----- Presentation timer is inactive
"?" [CR]
"000_%a_%b_%c" [CR]
%a...temperature sensor 1 status
%b...temperature sensor 2 status
%c...temperature sensor 3 status
"W"--- Exceeding critical temperature(Warning)
"S"--- Sensor temperature is safe.
%a
"N"--- Not relate to the temperature
%b
Ex. When "S_W_S"[CR] means that sensor 1 is safety
%c
temperature, sensor 2 is exceeding critical temperature,
and sensor 3 is safety temperature.
Note)Depends on projector Models, when the temperature
difference between sensor 1 and sensor 2 is over the specified
temperature, the sensor may show "W". In this case, sensor
3 shows that the temperature difference is "W", "S", or "N".
"?" [CR]
"000_%a_%b_%c" [CR]
%a=Temperature, sensor 1
%b=Temperature, sensor 2
%c=Temperature, sensor 3
(Ex.) "_31.5F" [CR]
_means a space. When the temperature sinks to -, the first
character "-"like "-05.5F" [CR].
%a
Last character indicates the sensor's status.
%b
Exceeding critical temperature ="F"
%c
Sensor temperature is safe
Not relate to the temperature="N"
"_31.5F"indicates 31.5 degrees and safety temperature.
When the temperature is safe, the data will be " 00.0S".
Every time the projector is reset, " 00.0S"is set.
In short, previous data is deleted.
"?" [CR]
="S"
Page
47