DORMA
•
1il~ 6. Troubleshooting
'{I
0
~~
Door remains open in the program
~
switch settings: AUTOMATIC,
~
PERMANT OPENING, and
PARTIAL OPENING
Basic module indicates error •.[ •.
(obstruction
during
commissioning)
Door does not open when the
program switch is set to:
AUTOMATIC, EXIT ONLY,
PERMANT OPEN, and
PARTIAL OPEN
Unpleasant operating noise
Control unit displays error code "H"
ES 200 Easy
ES 200
ES 200 20
Detector is emitting a continuous
signal
The learning cycle has not been
performed (the door weight is sti II
undetermined)
The blocking sensor is too sensiti-
ve for the door set (e.g. small,
high and heavy door leaves)
External detector
Internal detector
Screw presses against track roller
The basic module has been
connected to a 2D door system
and is expecting a FST mod ute.
ES 200
C048:
The rubber bell don't opens the
door
DAC 300
The solenoid don't held the
rubber belt.
Remove connector of radar motion
detector. If fault is cured by this,
replace radar movement detector
Perform learning cycle
Adjust blocking sensor to door set
with the help of the force
limitation
(OPEN, CLOSE) and the
delay time via the PDA
Remove activator connector and
bridge the input. If the fault is
cured by this, check supply
voltage (27 V) of the basic module
and the detectors. If it is okay
check and replace detectors if
required.
Remove activator connector. If the
door opens, check supply voltage
(27 V) of the basic module and
the detectors. If it is okay check
whether self-monitoring
detector
that works according to the fail-
safe principle
is connected.
Replace or trim screw
Restore original settings.
Perform a learning cycle.
ES 200 C048:
Check the rubber belt,
replace if required.
OAC
300
Check the solenoid and the
tension of the rubber belt,
replace if required.