dormakaba MUTO Premium XL150/80/120 / MUTO Comfort L80
Fixed Panel Installation Instructions
1.2

Tempered laminate glass (TLG) and adhesive specifications

Required parts for laminate glass
with MUTO System (not included)
3M™ Scotch-Weld™ Urethane
Adhesive, DP 605 NS
3M™ Scotch-Weld™ EPX™ Plus II
Applicator with 1:1 Plunger
3M™ Scotch-Weld™ EPX™ Plus II
Mixing Square Nozzle, 5.3mm
MUTO Accessory set (Clamp carrier
plate/gasket for TLG)
Handling time frame
NOTE: Door glass should not be installed until the full
cure time as been reached (see chart above).
1.1
Clean clamping area with alcohol-based
standard commercial cleaning agent before
mounting the glass hardware.
2 Scotch-Weld™ EPX™ Plus II Applicator with 2:1 and 1:1 Plunger is a trademark of 3M.
3 Scotch-Weld™ EPX™ Plus II Mixing Square Nozzle is a trademark of 3M.
MUTO Premium/Comfort Fixed Panel
4
Part Number
934.800
934.801
2
934.805
3
807.640
Function
Working life (time between
application and clamping of carrier)
Handling strength
Full cure time (ormal door usage not
recommended until full cure time has
been met)
936020
Quantity
Usage recommendation
1 tube
1 tube per 4 roller carriers
1 applicator
1:1 plunger with 934.800
adhesive
Pk of 4
4 nozzles per 1 tube of
adhesive
1 set
Time
5 minutes @ 75°F
20 minutes @ 73°F or more
48 hours @ 73°F or more
Important safety-related information for the mounting
and use of dormakaba glass hardware.
1.2
Never clamp metal glass fitting hardware
directly to glass surface.
1.3
Never use clamping product on surfaces with
self-cleaning coatings.
Technical specifications
05-2018