DOTECH FX3D Посібник користувача - Сторінка 2
Переглянути онлайн або завантажити pdf Посібник користувача для Регулятор температури DOTECH FX3D. DOTECH FX3D 4 сторінки. Digital temp controller
Dimensions and Panel Cut-Out Form
78
Wiring
FX3D
5A, 250Vac
OUT1
POWER
SUPPLY
L1
L2
1 2 3 4 5 6 7 8 9 10 11
100-240Vac,
50/60Hz
Sensor connection
NTC temp. sensor
COM
COM
NTC
COM
NTC
mA
NTC
mA
+VDC
mA
+VDC
+VDC
COM
COM
8 9 10 11
8 9 10 11
8 9 10 11
8 9 10 11
8 9 10 11
NTC
NTC
NTC
Constitution
(Function of Display Lamp and Button)
FX3D
OUT1
OUT2
Trip / Alarm Messages
Code
Menu
Internal Parameter Error
SYS
Sensor Open
OPN
Sensor Short
SHT
LLL
Lower Input
Higher Input
HHH
Lower Low Limit
ALL
Higher High Limit
ALH
8
35
4~20mA TRANS.
OUT2
NTC
COM
NTC
mA
+VDC
c
4~20mA
4~20mA loop
signal input
power sensor
NTC
COM
NTC
mA
NTC
mA
+VDC
mA
+VDC
+VDC
COM
COM
NTC
COM
NTC
8 9 10 11
8 9 10 11
8 9 10 11
8 9 10 11
In case of error occurring, the following messages are flickering at every 0.5 sec. intervals.
※
In Case of change of set value by an unknown case.
In case of Input sensor open wire(Normal operation after sensor connecting)
In case of Input sensor short circuit
Lower sensor input than measuring range
Higher sensor input than measuring range
Lower Low Limit Alarm than Low Limit Alarm Value
Higher High Limit Alarm than High Limit Alarm Value
70
28
40
UNIT : mm
NO
Connection
1
POWER
2
3
4
5
6
7
8
9
10
11
Option Module connection
-A1 Model
4~20mA Output
mA
NTC
mA
+VDC
mA
+VDC
+VDC
1
2
4~20mA
3
4~20mA
4
SG
OUT1
OUT2
LED
°C / °F
PRG
SEL
BUTTON
▲
▼
PRG + ▼
Description / Instructions
- 2 -
90
Description
100-240Vac, 50/60Hz
Relay output OUT1 when closed
OUT1
Common signal
Relay output OUT1 when closed
OUT2
Common signal
Relay output OUT1 when open
Common signal
COM
NTC
Temp. sensor input
mA
4~20mA signal input
+Vdc
4~20mA sensor power (12Vdc)
-R4 Model
RS485 COMM.
1
RED
2
TRX
RED
3
WHITE
WHITE
TRX
BLACK
4
SG
BLACK
Turn on when output #1 is ON (Flickering at standby)
Turn on when output #2 is ON (Flickering at standby)
Celsius / Fahrenheit display units
ON at trip, Flickering at alarm
Parameter set up locked
Use at program setup
Execute selected menu or Input setup value
Move between menus & Increase setup value
Move between menus & Decrease setup value
If pushing for 10 sec. at the same time ,
setup value is initialized
Response at
Detection
Immediate Stop
Immediate Stop
Immediate Stop
Immediate Stop
Immediate Stop
Immediate Stop
Immediate Stop
(Panel Cut-Out : 71mm X 29mm)
-A1R4 Model
4~20mA Output
& RS485 COMM.
1
TRX
RED
2
TRX
BLUE
3
4~20mA
WHITE
4
4~20mA
BLACK
Reset Type
Automatic Reset
Automatic Reset
Automatic Reset
Automatic Reset
Automatic Reset
Automatic Reset
Automatic Reset
R20150924