DOTECH DPX100-150-R4-MPA Посібник користувача - Сторінка 3
Переглянути онлайн або завантажити pdf Посібник користувача для Перемикач DOTECH DPX100-150-R4-MPA. DOTECH DPX100-150-R4-MPA 4 сторінки. Digital pressure switch
4.
PARAMETER
:
PARAMETER CHANGE
● If there was no input for 3 minutes during setup, it will be returned to operation mode
● If PRG button is pressed at any step, it returns to operation mode.
※ This manual is based on the standard model for MPa and the displays and settings of pressure unit are
subject to change depending on the models for other pressure units.
: PARAMETER SETTINGS OF GROUP 1
No
Menu
Step 1 ON Pressure
4 0031
Step 1 OFF Pressure
4 0033
Step 2 ON Pressure
4 0041
Step 2 OFF Pressure
4 0043
Step 3 ON Pressure
4 0051
Step 3 OFF Pressure
4 0053
※ STEP CONTROL OF PRESSURE
Depressurization Control : After comparing the ON pressure of each step, it outputs a signal from the lowest pressure.
Ex.) If ON steps are set(Step 1: 14.0, Step 2: 1.50, and Step 3: 1.60), it begins from the lowest(Step 1) and moves to the next steps in order(→ Step 2 → Step 3).
Pressurization Control : After comparing the ON pressure of each step, it outputs a signal from the highest pressure..
Ex.) If ON steps are set(Step 1: 16.0, Step 2: 1.50, and Step 3: 1.40), it begins from the highest(Step 1) and moves to the next steps in order(→ Step 2 → Step 3).
※ The pressure range depends on a model.
Model
DPX100-115
DPX100-050
(PRG Button Press for 3 seconds)
Code
Unit
Step
1ON
MPa
0.01
1OF
MPa
0.01
2ON
MPa
0.01
2OF
MPa
0.01
3ON
MPa
0.01
3OF
MPa
0.01
Min
Max
-0.10
1.50
-0.10
5.00
Min
Max
DPX100-115
-0.10
5.00
1ON - 0.01
-0.10
-0.10
5.00
2ON - 0.01
-0.10
-0.10
5.00
3ON - 0.01
-0.10
※ The OFF pressure range depends on a control type.
Control Type
DN(Depressurization Control)
Step OFF pressure must be set under ON pressure.
UP(Pressurization Control)
Step OFF pressure must be set over ON pressure.
-3-
Default
DPX100-150
0.30
1.40
0.20
1.30
0.45
1.50
0.35
1.40
0.50
1.60
0.40
1.50
Min
-0.10
1on- 0.01
1on+0.01
DPX100 R20141014
CustomSetup
Max
5.00