elecTric al cOnnecTiOns
3.1 installation connections
Recommendation:
Connection to the grounding system: locally or
from the distance (cable 1 x 0,75 mm2).
Electrical panel
3 x 0,75 mm
(Optional)
+14 V
Door
opening
button
GND
C/D
AUX
BUT
LC
DC
Electro-
magnetic
LA/C
Lock
(Open collector)
AC
LA
APE.1Sx
APE.1Fx
Outdoor panel
hub details
+
 (+14 V d.c.; 2A) general feed of the installation
+14 V
(except for video communication)
0 V (mass) general feed of the installation
GND
audio and data communication
C/D
+
 monitor display feed (+14 V d.c.)
+Uv
0 V (mass) monitor display feed
-Uv
0 V (mass) video signal reference
GNV
(1 V vv) video signal input (also valid for V1, V2, V3 and V4)
Vin
(1 V vv) video signal output
Vout
+
(+12 V d.c.; 0,2 A) external video camera feed
Ucam
auxiliary command output (open collector)
AUX
connection for a doorbell button
Dbl
connection for opening the lock
BUT
DC lock command
LC
DC/AC lock common
LA/C
AC lock command
LA
+
 accumulator connection (+12V; max. 7 Ah)
+ACC
-
 accumulator connection
-ACC
F
phase (230 V a.c. / 50 Hz)
null
N
earthing
Hubs specific to ELECTRA locks
connection for opening the lock
BY
+Y
feed for Electra DC lock
Y
Y1
feed for Electra AC lock
Y2
230 Va. c./50Hz
2
F
Cable
N
ORANGE
+14 V
BROWN
GND
GREEN
C/D
BLUE
(DATA)
-Uv
UTP CAT5
(AWG 24)
GNV
Vin
Auxiliary
SAC.V1A.DIN
command
Power Supply
Accumulator
ACC
12 V/1,3 Ah
2 x 0,5 mm
2
Cable
-ACC
+ACC
ORANGE
+14 V
BROWN
GND
GREEN
C/D
BLUE
(DATA)
+Uv
UTP CAT5
(AWG 24)
GNV
Vin

3.2 lock connections

Drive current (DC)
3 x 0,5 mm
2
Cable
BY
BUT
+Y
LC
Y
LA/C
LA
YEM.22x
Electromagnetic lock
Outdoor panel
Drive Current (DC)
Alternative current (AC)
BUT
2 x 0,5 mm
LC
Cable
LA/C
LA
Outdoor panel
BY Y2 Y1
YEM.32x
Electromagnetic lock
Alternative current (AC)
BUT
2 x 0,5 mm
2
LC
Cable
LA/C
LA
Outdoor panel
Electromagnetic lock
Alternative current (AC)
Indoor terminal
Main
(Optional)
+14 V
Doorbell
GND
button
C/D
DBL
ORANGE
+14 V
BROWN
GND
GREEN
C/D
BLUE
Dbl
UTP CAT5
(AWG 24)
ATE.Sxx
Indoor terminal
Main
4 x 0,5 mm
...
2
Cable
GND
GND
...
BY
BUT
+Y
LC
Y
LA/C
LA
YEM.21x
Electromagnetic lock
Outdoor panel
Drive Current (DC)
2
12 Va . c .
230 Va . c .
Transformer
12 Va . c .
230 Va . c .
Transformer
(Optional)
+14 V
GND
C/D
ATE.Sxx
ATB.Sxx
Indoor terminal
additional
page 4/6