Baumer GNAMG Series Посібник - Сторінка 28
Переглянути онлайн або завантажити pdf Посібник для Аксесуари Baumer GNAMG Series. Baumer GNAMG Series 41 сторінка. Inclination sensor with canopen interface
Object 2300
Customer EEPROM section
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameter
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameter
Object list according to DS 410
Object 6000
Resolution
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Object 6110
Slope angle Y- axis (Slope long) (not at 360° sensor)
SubIndex
Data type
Access
Default
EEPROM
Meaning
Parameters
Manual_GNAMG_CANopen_EN.doc
21.11.12
0
Unsigned 8
ReadOnly
8h
No
Any optional data can be saved in this object
8
1...8
Unsigned 16
ReadWrite
0h
Yes
One 16 bit parameter per each subindex (load in EEPROM by object 1010h)
0
0
Unsigned 16
ReadWrite
0001h =
0.001°
Yes
Resolution
0001h =
0.001°
000Ah =
0.01°
0064h =
0.1°
03E8h =
1.0°
0
Integer 32
ReadOnly
No
Slope angle
Value range
Depending on the device type (measuring range) and parameter in 6000h
(resolution):
(+measuring range)/resolution ... to ... (-measuring range)/resolution
Example:
measuring range = ±30°
Resolution = 0,001
Value range: +30000...-30000
28/41
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany