Process Data

3.2
With the sensor in the IO-Link communication mode, process data is cyclically exchanged between the IO-
Link master and the device. Process data is exchanged to and from the sensor (SensorMaster). The
master does not need explicitly to request these data.

Process Data-In

3.2.1
Process Data-In is sent from the sensor to the master (Sensor  Master). As shown in Figure 4 IO Link
Process data Input" and the peak data of 5 peaks Figure 5 Process data Input of 5 peaks", the Process Data
Input is an 208 bit string.
47
IntegerT(32)
Measurement value
(MDC)
207
192
191
176
16 bit
16 bit
Peak 4
Peak 4
Amplitude
Distance
Bit 0/Bit 1: SSC1/SSC2 (Switching Signal Channel 1 & Channel 2)
These bits are the digital representation of the switching outputs.
Bit1 = 0 → There is no object within the switching range (Logic: Normal)
Bit1 = 1 → An object lies within the switching range (Logic: Normal)
See section 4.3 to configure
Bit 2: Quality
This bit provides information about the quality of the received signal coming from the object.
Bit2 = 0 → Sensor has enough signal to detect an object reliable
Bit2 = 1 → The signal detected from the sensor is critical.
Bit 3: Alarm
The alarm bit indicates that there is a problem with the configuration or function of the sensor.
Bit3 = 0 → Sensor operates properly.
Bit3 = 1 → A problem with either the sensor configuration or function was detected.
Bit 5: Switching Signal Channel 4 (SSC4), Switch Counter Function
By configuring SSC4, it is possible to set up a binary signal related to the number of switch counts of SSC1
or SSC2. An auto-reset and time filter are included, to be able to create a full-featured counter being able to
count lot sizes without any need to code software on the PLC.
See section 0 to learn how to configure this bit.
Bit 8 to 15: Scale
Value is the exponent to the power of ten, applicable to the value of the Measurement Data Channel (MDC)
Example:
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
IO-Link Process Data Input
16
15
8
7
IntegerT (8)
Scale
Figure 4 IO Link Process data Input
IO-Link Process Data Input (peak data)
175
160
159
144
143
16 bit
16 bit
Peak 3
Peak 3
Peak 2
Amplitude
Distance
Amplitude
Figure 5 Process data Input of 5 peaks
Baumer specific
7
6
5
4
SSC4
128
127
112
111
16 bit
16 bit
16 bit
Peak 2
Peak 1
Distance
Amplitude
8/40
8 bit
3
2
1
Alarm
Quality
SSC2
96
95
80
79
64
16 bit
16 bit
Peak 1
Peak 0
Distance
Amplitude
Baumer Electric AG
Frauenfeld, Switzerland
0
0
SSC1
63
48
16 bit
Peak 0
Distance