6 Technical data
Measuring range MR
1)
Resolution *
2)
Linearity error *
3)
Response time *
4)
Ambient light *
Typ. Temperature coefficient *
Light source
Laser classification (per IEC
60825-1/2014)
Wave length
6)
Laser spot *
7)
Laser line*
high
width
Analog output
Load resistor U
Out
Load resistor I
Out
Alarm output
Voltage supply range
Supply current
Reverse polarity protection
Short circuit protection
Housing material
Tightening torque
Protection class
Temperature range
Storage temperature
1)
2)
*
and *
measured on white ceramic sheet
3)
*
the response time depends on the reflectivity of the object
*4)
max. sunlight on a white measuring surface
*5)
xx% of full scale measuring range / °C
6)
7)
*
and *
dimension of laser beam:
BA_OADM20x5.doc ANW_81253059
03.07.2017
5x40/S14F
5x60/S14F
30...50 mm
< 0,01 mm
0,05 ... 0,07 mm
± -0,03
± 0,15...± 0,22 mm
< 10 ms
< 50k Lux
0.015%
5)
of MR/°C
2...1.5 mm
2 mm
1...0.4 mm
OADM 20x54xx/S14F diameter
Ø – beam
OADM 20x
5x70/S14F
30...130 mm
50...250 mm
0,1 ... 0,3 mm
± 0,3 ... ± 0,8 mm
< 10 ms
< 10 ms
< 40k Lux
< 8k Lux
0.03%
0.03%
of MR /°C
of MR/°C
Laser diode red, pulsed
Laser class 2
656 nm
2...1 mm
2.7 mm
3...5 mm
4...10 mm
2...1 mm
2.5 mm
4 – 20 mA or 0 – 10 V
> 100 k
< (+Vs – 6 V) / 0.02 A
PNP / max. 100 mA
12 – 28 VDC
< 100 mA, (at + 24V ~ 40mA)
yes (voltage supply only)
yes
Die-cast zinc
1.0 Nm
IP 67
0°C .. +50°C (non condensing)
-20°C .. +70°C
measuring
height
range
25/30
5x71/S14F
100...500 mm
0,2 ... 0,5 mm
± 0,8 ... ± 2 mm
± 1,2 ... ± 7,2 mm
< 10 ms
< 10k Lux
0.04%
of MR/°C
2.7...3.0 mm
5.5...18 mm
2.5 mm
OADM 20x55xx/S14F size laser beam
measuring
range
width
Frauenfeld, Switzerland
5x80/S14F
100...600 mm
0,2 ... 0,5 mm
< 10 ms
< 10k Lux
0.06%
of MR/°C
2.7...3.0 mm
-
Baumer