Baumer OM20 Посібник з експлуатації - Сторінка 39

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Аксесуари Baumer OM20. Baumer OM20 48 сторінок. Laser distance sensors

Baumer OM20 Посібник з експлуатації
Baumer
9.3

Exposure reserve

The exposure reserve indicates the light quantity reflected by the measurement object (as a rel-
ative factor without unit). The exposure reserve helps you with the following problems, among
others:
Check whether a valid measurement result is present (signal quality). The signal quality is
n
weak
▪ when the sensor is not optimally aligned, and
▪ when the distance between the sensor and measurement object is too large.
During ongoing operation: Check the front panel of the sensor for soiling – if the exposure
n
reserve decreases over time, it may be an indication of increased soiling of the front panel.
Use the histogram function for this purpose
IO-Link diagnostic data: Exposure reserve
Name
Exposure Reserve. Exposure Reserve
9.4

Signal quality

The signal quality serves as an indication of the reliability of the measurement.
IO-Link diagnostic data: Signal quality
Name
Exposure Reserve.Quality
Level
OM20/OM30 | V1
(Histogram function
Description
Output of the exposure reserve.
Description
Output of the signal quality.
n
▪ 0 = Valid signal
▪ 1 = Weak signal
Low signal quality can result in greater measured value er-
rors. Decrease the distance to the measurement object or
optimize the alignment of the sensor.
▪ 2 = Critical signal
Valid measured value acquisition is no longer guaranteed.
Decrease the distance to the measurement object or opti-
mize the alignment of the sensor.
LEDs blink if a critical signal is reached.
The alarm output is activated when no measured value can
be recorded anymore.
Operating Manual
Diagnostic data
[} 41]).
|
9
39