Baumer OM30 Посібник з експлуатації - Сторінка 29

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Аксесуари Baumer OM30. Baumer OM30 48 сторінок. Laser distance sensors

Baumer OM30 Посібник з експлуатації
Baumer
8.6

Switching points

Via the Switching points function, distances (switching points) are defined at which the switching
output is to be activated.
The function can be configured via the following parameters:
Select measurement mode (point mode or window mode).
n
Define the position of the switching points (SP1 and SP2):
n
▪ Point mode: SP1
▪ Window mode: SP1 and SP2
Point mode
1
0
Ill. 10: Sensor in the point mode measurement mode
Purpose/application (example):
n
▪ Quality control: Check the minimum/maximum height of a measurement object.
▪ Reach a desired position with a tool that edits an object.
Window mode
1
0
Ill. 11: Sensor in the window mode measurement mode
The smallest switching window is 2 mm.
n
Purpose/application (example):
n
▪ Quality control: Check the dimensions of a measurement object within a tolerance win-
dow.
IO-Link parameter: Switching points
Parameter name
SSC1 Config.Mode Disabled,
SSC1 Param.SP1
SSC1 Param.SP2
OM20/OM30 | V1
SP1
SP1/SP2
SP1/SP2
Values
Single
Point, Window
-
-
Description
Selecting the switching output mode:
n
▪ Point mode: (switching point SP1)
▪ Window mode (SP1 and SP2)
Distance at which the SSC1 is activated or inacti-
n
vated.
Distance at which the SSC1 is activated or inacti-
n
vated. Only relevant for window mode.
Operating Manual
Functions
|
8
29