Baumer GBLMW Посібник - Сторінка 13
Переглянути онлайн або завантажити pdf Посібник для Конвертер мультимедіа Baumer GBLMW. Baumer GBLMW 41 сторінка. Absolute encoders with profinet interface with bus cover
Також для Baumer GBLMW: Посібник (19 сторінок), Посібник (26 сторінок), Посібник (24 сторінок)
Device-specific parameters
Code sequence
Behaviour of the position data in relation to the sense of rotation of the encoder shaft when looking at
flange.
CW („clockwise") = Ascending values with clockwise rotation
CCW („counter-clockwise") = Ascending values with counter-clockwise rotation
Class 4 functionality
If active („enabled"), the encoder operates as a Class 4 Device of the encoder profile.
If not active ( „disabled), the encoder operates as a Class 3 Device of the encoder profile.
Here setting a preset is disabled.
G1_XIST1 affected by preset
If active ("Yes"), setting a preset will affect both the left-aligned position value G1_XIST1 and the
right-aligned position value G1_XIST2.
If not active ("No"), the left-aligned position value G1_XIST1 is not added an offset that is internally
calculated upon setting a preset. In this case, both position values G1_XIST1 and G1_XIST2 may be
different!
Scaling function control
If active ("enabled"), resolution („steps per revolution", "measuring units per revolution") and the total
measuring range can be parameterized at will within the admissible limits.
If not active ("disabled"), the previous encoder settings for resolution and total measuring range will
remain, i.e. the maximum limits. Any try to enter deviating parameters will result in a parameterization
error signal.
Measuring units per revolution
Parameterization of the required resolution („steps per revolution", „measuring units per revolution").
Admissible values range from 1 to the maximum encoder resolution. Usually the limits are indicated
in the parameterization software.
multivoPlus encoders require a 32 bit value here to get two input fields, i.e. „measuring units per
revolution (hi)" and „(lo)". Ho to split the 32 bit value into two 16 bit values please see under 8.1.4.
A re-parameterization may clear the previous offset value (see "note" under 6.6. Preset function).
Total measuring range (units)
Parameterization of the required total measuring range, „TMR".
Singleturn encoders require here the same parameter as for the resolution ("Measuring units per
revolution").
Admissible values range from 2 to the product of programmed resolution multiplied by maximum
number of revolutions. The maximum limit of the parameterization software is only applicable if the
resolution is also the maximum.
All multiturn encoders and multivoPlus singleturn encoders need a 32 bit value here to get two input
fields, „Total measuring range (units) hi" and „lo". How to split up the 32 bit value into two 16 bit
values please see under 8.1.4.
Any alteration of the total measuring range clears the previous offset value (see "note" under 6.6
Preset Function)
Manual_ProfibusDPV2_BIDE_EN.docx
22.11.12
13/41
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany