Douglas Dynamics 77750 Інструкція з монтажу Посібник з монтажу - Сторінка 12
Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Автомобільні аксесуари Douglas Dynamics 77750. Douglas Dynamics 77750 17 сторінок. Snowplow
OPERATIONAL TEST AND FINAL ADJUSTMENTS
HYDRAULIC UNIT
WARNING
Keep 8' clear of the blade when it is being
raised, lowered, or angled. Do not stand
between vehicle and blade or directly in front
of the blade. If the blade hits or drops on you,
you could be seriously injured.
The hydraulic unit comes from the factory
preassembled, partially filled, and fully tested.
1. Attach the snowplow to the vehicle according to
the instructions on the back of the blade.
2. Remove the cover from the hydraulic unit. Remove
and discard the factory‑installed pipe plug from
the top of the reservoir and install the breather.
AeroShell
is a registered trademark (
®
Lit. No. 52238, Rev. 05
Breather
) of Shell Oil Company.
®
To prevent accidental movement of the blade,
always turn the control OFF whenever the
snowplow is not in use. The power indicator
light will turn OFF.
3. Turn the control ON and raise and lower the
snowplow several times. With the snowplow in the
raised position, fully angle the snowplow from right
to left several times. Activate the control FLOAT
function and make sure the blade is lowered
completely to the ground. Turn the control OFF.
Do not mix different types of hydraulic fluid.
Some fluids are not compatible and may
cause performance problems and product
damage.
4. Remove the breather and check the fluid
level. The fluid level should be 1"–1-1/2" below
the fill hole. If additional fluid is needed, add
SnowEx
Rapid Action Hydraulic Fluid rated
®
to –40°F (–40°C), or other fluid conforming to
Military Specification MIL-H-5606 A, such as
Mobil Aero HFA or Shell AeroShell
fluid is 1"–1-1/2" below the fill hole.
NOTE: Loosen the breather slowly to relieve any
pressure in the reservoir.
NOTE: Add fluid only when all rams are retracted
and blade is resting fully on the ground.
5. Replace and tighten the breather.
12
WARNING
CAUTION
Fluid 4 until
®
July 15, 2020