8
|
Electrical installation
8
Electrical installation
8.1
Pin assignment
8.2
Electrical connection
Condition:
ð Mains voltage supply must be within the admitted sensor limits (11 - 35 V
ð Power supply provides external overload protection.
ð Connections will use only approved fire protection cables.
ð Any long or hanging cables are secured by approved fastening systems.
ð All electrical connections are clean.
CAUTION
Risk of damage to equipment by electric current
NOTICE
Risk of damage to equipment by contamination
NOTICE
Damage to seal or push-in fitting
Excessive tightening of the union nut may damage the connection or the O-seal provided at the
M12 cable.
a) Tighten the union nut to a maximum torque of 0.6 Nm.
b) Never use any tools to tighten the union nut.
NOTICE
Observe circuit diagram
Observe the wiring and circuit diagrams when preparing electrical connection.
Instruction:
a) Make sure the higher-level machine is safely switched off and not under supply.
If necessary, disconnect the higher-level machine and secure the control cabinet against in-
advertent power-on.
b) Connect the sensor to the control cabinet using the connector.
c) Ensure correct pin assignment.
16
1
Vs +
3
GND (0 V)
5
Select
2
Iout + / SW2
4
IO-LINK / SW1
Operating Manual
Power supply (+)
Power supply (-)
Select range: R1 or R2
Select output: conductivity or temperature
4 ... 20 mA
Conductivity / temperature / SW
IO-Link / SW
Baumer
).
DC
PAC50H/S | V1