Fault
Scatec counts less
1
copies than actually
pass the sensor
Manual SCATEC-2
Version 2021-09
Possible causes
a) Wrong sensitivity setting.
b) Copies too close to or too far away
from the Scatec, so that the copies
are in a distance range at which the
sensitivity of the sensor is inadequate.
c) Overlap spacing sporadically too
small.
d) Some copies are completely
covered by another copy.
e) Conveying speed too high.
f) False pulse suppression active
while overlap a is highly irregular or
conveying speed is occasionally
accelerated very quickly.
Corrective actions (see manual section x.x)
Set DIP-swich 4 off. (8; 9.3)
Set the distance of the copies in a range where
the sensor is sufficiently sensitive to detect the
copies. (10.6)
Increase the overlap spacing or reduce the
conveying speed (production rate). (9.1)
Prevent complete coverage of copies.
Reduce conveying speed. (10.6)
Deactivate false pulse suppression (DIP-switch 3
set off) or make overlap a more regular or
accelaerate slower (9.2)
32