Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns
or death
Hazardous
machinery can
cause serious
personal injury.
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury or property damage.
Hazardous pressure
can cause serious
personal injury or
property damage
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior
to performing service or maintenance
Hazardous or toxic
fluids can cause
serious injury.
SCHEDULED MAINTENANCE
STRAINERS
Strainers must be cleaned regularly to avoid pump starvation.
Schedule will depend upon the application and conditions.
MAINTENANCE
Hazardous voltage.
Can shock, burn or
cause death.
Hazardous pressure
can cause serious
personal injury or
property damage
Maintenance shall be performed by qualified
technicians only, following the appropriate procedures
and warnings as presented in this manual.
LUBRICATION
To avoid possible entanglement in moving parts do not
lubricate pump bearings, gear reducer or any other parts
while the pump is running.
Pump bearings should be lubricated every one to twelve
weeks (AT MINIMUM), depending on the application, and
operating conditions.
Recommended Grease:
Dow Corning
DuPont
Greasing Procedure:
1. Remove the grease relief fittings (76A) from the bearing
covers (27A).
2. SLOWLY apply grease with a hand gun until grease
begins to escape from the grease relief fitting port. (76)
3. Replace the grease relief fittings (76A).
DO NOT overgrease pump bearings. While it is normal for
some grease to escape from the grease tell-tale hole after
lubrication, excessive grease on pumps equipped with
mechanical seals can cause seal failure.
701-A00
Page 6/12
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Failure to relieve system pressure prior
to performing pump service can cause
serious personal injury or property
damage. Systems with meters will still
be pressurized even after the hose is
emptied
NOTICE:
NOTICE:
MOLYKOTE 44
® -
KRYTOX GPL 203
® -