Specifications

Electrical
Model number
MC400 series icemaker
Ambient specifications
Air temperature
Water temperature
Water pressure
Plumbing
Your new icemaker is equipped with a drain line to simplify draining the evaporator and float reservoir. The tube
labeled "float/evap drain" is for SERVICE USE ONLY and must NOT be connected to the icemaker drain.
Water line sizes
Drain line sizes
Slope to drain
Water shut-off recommended within 10 feet (3m), drain to be hard-piped and insulated
Separate drains for icemaker and condenser. To prevent back flow, do NOT connect drains.
Follett recommends installation of a Follett water filter system (part# 00130229) in icemaker inlet water line
Field Wiring: countertop dispensers with Satellite-fill icemakers
Consult enclosed D400A/W, R400A/W, MCD400A/W manual.
115/60/1
100˚F/38˚C max.
90˚F/32˚C max.
70 P.S.I. max.(482kPA) 10 P.S.I min. (89kPA)
Make up water (inlet to float)
Condenser (water-cooled only)
Icemaker drain
Condenser (water-cooled only)
1/4" per foot (6mm per 30.4cm run)
4
Full load amps
11.0 amps
50˚F/10˚C min. (best performance below 80˚F/27˚C)
40˚F/4˚C min. (best performance below 70˚F/21˚C)
1/4" min.
3/8" min.
3/4" min.
3/8" min.
1/2" min.
Max. fuse size