Follett HCC1410ABS Посібник - Сторінка 7
Переглянути онлайн або завантажити pdf Посібник для Льодогенератор Follett HCC1410ABS. Follett HCC1410ABS 8 сторінок. Self-contained chewblet ice machine
Також для Follett HCC1410ABS: Інструкція з монтажу Посібник з монтажу (17 сторінок), Посібник із швидкого старту (8 сторінок)
4 – Horizon Elite ice machine mounting accessories
Optional wall mount bracket
30.50"
(77.7 cm)
5 – Horizon Elite drain - specifier guidelines
Flush drain plumbing – For regular machine drainage
Chassis drain plumbing – To assist with condensate in high humidity areas
Self-contained 1010, 1410 series ice machine
Optional machine stand
22.00"
(55.9 cm)
A - 25.2" (64.0 cm)
25.50"
B - 28.7" (72.9 cm)
(64.8 cm)
➊
Minimum 8"
radius
2 ft x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
➋
3/4" MPT x 1" slip
➌
1" Stand pipe/drain
6.88"
(17.50 cm)
A
B
13.00"
(33.0 cm)
21.00"
(53.3 cm)
Important specifier notes: Where code
allows, follow recommendation below.
1. Connect the silicone tubing to the ice machine 3/4"
2. Assemble the 3/4" barb x 3/4" FPT to the 3/4" MPT x
3. Connect the 1" slip fitting to the 1" stand pipe/drain
Important specifier notes: Where code
allows, follow recommendation below.
1. Plug must be removed from John Guest fitting.
2. Route 3/8" drain tubing through knockout in back of
3. Drain must slope 1/4" inch per foot ( 6 mm per 30.4 cm).
Important specifier notes
1. For secure wall mounting, specify optional
wall mount bracket.
2. Wall and fasteners must support the weight
of the ice machine, bracket, supply water and
ice. Use of a backing board may be required
with hollow wall construction.
3. Machine stand mounting adds 6.88"
(17.48 cm) to height of ice machine.
4. No dips in tube routing allowed.
5. Ice transport tube needs minimum 1/4"
per foot (2 cm per meter) pitch toward ice
machine and should be secured to prevent
dips and traps from forming.
➊
drain barb
.
1" slip. Connect the other end of the silicone tubing to
➋
the 3/4" barb
.
Note: Minimum 8" radius on silicone drain line. Drain line
from the ice machine must have at least 1/4" per foot
pitch (6.4 mm/0.3 m).
Note: Stand pipe/drain provided by others. All other
components provided with ice machine.
docking station and insert fully into John Guest fitting
connection at the rear of the machine chassis. Route
other end of 3/8" drain tubing to drain.
➌
.
7
Form# 7030