Follett Chewblet 7 Series Посібник з монтажу - Сторінка 17

Переглянути онлайн або завантажити pdf Посібник з монтажу для Диспенсер для води Follett Chewblet 7 Series. Follett Chewblet 7 Series 20 сторінок. Ice and water dispenser

Follett Chewblet 7 Series Посібник з монтажу
LED Indicator Description
The LED Indicator is located behind the front panel.
Fig. 16
LED Name
LED Color
Clean
Green
N/A
PM
Red
Drip tray
Red
Water leak
Red
High amps
Red
Service
Red
Maintenance
Yellow
Low water
Yellow
Time delay
Yellow
Sleep cycle
Green
Making ice
Green
Low bin
Green
Power on
Green
The dispenser is in Cleaning Mode. Dispenser is disabled to allow for cleaning of front panel.
Not used.
Six-month periodic maintenance required.
Drip tray full.
Internal leak in dispenser.
Auger gearmotor has exceeded 0.55A (0.33A for 230V). The HI amps and Time delay
LEDs will illuminate, the machine will shut down for one hour, the LEDs will turn off, and the
machine will resume normal operation.
8000 hour bushing check (call Follett technical service group at (877) 612-5086 or
+1 (610) 252-7301).
Enter Maintenance Mode by pressing and holding maintenance/clean switch for 5 seconds.
Unit will not make or dispense ice.
Insufficient water supply to machine or no low bin LED upon startup.
Ice production will not resume for at least 15 minutes after a full bin is achieved and a
minimum amount of dispense activity has elapsed.
After a full bin and 10 minutes of non-use, the unit goes into standby and will not produce ice
until either:
7 Series: 12 hours has elapsed, 15 Series: 4 hours has elapsed or ice has dispensed.
Gearmotor, compressor, and fan motor energized.
Bin switch closed calling for ice.
Power supplied to unit.
Description
Dispenser and Ice Machine - 115 V, 230 V, 220 V
17