Follett EU155N Series Посібник з монтажу, експлуатації та обслуговування - Сторінка 7

Переглянути онлайн або завантажити pdf Посібник з монтажу, експлуатації та обслуговування для Диспенсер для води Follett EU155N Series. Follett EU155N Series 20 сторінок. Ice and water dispensers
Також для Follett EU155N Series: Посібник з монтажу та обслуговування (20 сторінок), Посібник з монтажу, експлуатації та обслуговування (20 сторінок)

Installation ––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Installing EU155N dispenser in counter

All EU155N dispensers must be installed level in both directions and supported from below with 153
!
– 229mm adjustable legs provided, or channels installed on site. DO not hang dispenser on fl ange of
counter.
1. Check that dispenser location meets all requirements in this manual and cut counter as shown.
2. Block up area below counter cut-out to support dispenser when lowered into place.
3. For automatic load dispensers, disconnect ice transport tube from bracket in storage area of dispenser. (Since
this tube must be reinstalled in bracket after dispenser is dropped into counter, note how tube is held by bracket
tabs before disconnecting.)
4. Carefully lower dispenser into counter until it rests on support blocks.
5. Adjust height from below with standard leg kit until dispenser fl ange rests fl ush with counter.
6. Apply a bead of NSF listed silicone sealant (Dow-Corning RTV-732 or equivalent) approximately 6mm in
diameter around perimeter of dispenser where it meets counter and smooth sealant to a 4mm radius.
7.
Install a hard drain line, maintaining at least a 6mm per 304mm run slope, and insulate line to prevent
PVC pipe is suggested. Care must be taken in sweating any metal drain pipe used. Excessive heat
!
applied while sweating metal pipe may melt plastic fi tting on dispenser. condensation.
8. Make electrical connections in accordance with applicable wiring diagrams provided, as well as NEC and local
codes. Provide disconnects within 3m of dispenser and ice machine for servicing.
Counter cut-out
(772mm)
+3mm
- 3mm
Front of counter
(667mm)
+3mm
- 3mm
EU155N Ice and Water Dispensers
7