TANK ASSEMBLY
MB2200‐10 (Standard)
MB2200‐20 (Tall)
TANK ORIFICE
MB1409‐x
1 = Lean Mixture (less abrasive)
5 = Rich Mixture (more abrasive)
Tank Orifice & Bypass Tube
BYPASS TUBE
MB2265‐x
We have configured the AccuFlo® for your
particular application.
Start with these settings.
You have the option to adjust settings. Minor
changes in powder concentration should be made
with the Abrasive Blend Control on the front panel.
For more significant changes, the abrasive
concentration in the air stream can be made
leaner (less abrasive) or richer (more abrasive) by
changing the tank orifice and bypass tube. Contact
a Comco Tech Support Specialist for information on
additional options.
• Change the tank orifice using a ¼" nut driver.
• Unscrew the bypass tube and lift it out of the
sleeve. Using the chart below, select the tube
you desire and insert it in the sleeve.
Finger tighten only do not force.
Bypass Tube Chart
Standard Tank ‐1C ‐1B ‐1A
Tall Tank ‐2C ‐2B ‐2A
TANK ORIFICE
MB1409‐
BYPASS TUBE
MB2265‐
1
2
‐18
2
3
‐25
3
4
‐30
www.comcoinc.com