Follett Edge Series Посібник з монтажу - Сторінка 8

Переглянути онлайн або завантажити pdf Посібник з монтажу для Морозильна камера Follett Edge Series. Follett Edge Series 17 сторінок. Laboratory freezer
Також для Follett Edge Series: Посібник з монтажу (17 сторінок)

Follett Edge Series Посібник з монтажу
Control Panel Functionality Check
The first time the unit is powered on, follow the operation below to ensure control panel functionality.
Manual check of Control Panel
Operation
1
Connect to the power
source.
2
Press "Alarm Test" key.
3
Press "Alarm Test" key.
4
Press "SET" key.
5
Press
key.
6
Press
key two times.
7
Press
key three times.
9
Open the door
10
Close the door
11
Open the door
12
Keep the door open
13
Close the door
8
REFNAT5-SD, REFNAT5-GD
Key operated
-----
Five seconds after turning on the unit, the
temperature inside the unit should appear on
temperature display (LED Screen).
ALARM TEST
Two seconds after pressing the button, the buzzer
should sound every 1 second. Let the buzzer sound
at least 3 times.
ALARM TEST
Within 2 seconds of pressing the button, the buzzer
should stop. (The buzzer should stop sounding after
two second of pressing the button).
SET
Within 2 seconds of pressing the button, you will
hear a beep once. The display will show "5.0" on
LED Screen and it will start blinking.
Within 2 seconds of pressing the button, you will
hear a beep once. The display will show "4.9" on
LED Screen and it will start blinking.
Within 2 seconds of pressing the button, you will
hear a beep once. The display will show "4.7" on
LED Screen and it will start blinking.
Within 2 seconds of pressing the button, you will
hear a beep once. The display will show "5.0" on
LED Screen and it will start blinking.
-----
Two seconds after opening the door, the door check
lamp will turn red.
-----
Two seconds after closing the door, the door check
lamp will turn off.
-----
Two seconds after opening the door, the door check
lamp will turn red.
-----
After 120 seconds, the alarm LED will turn red and
will start beeping every second. Let the unit beep at
least 3 times.
-----
Two seconds after closing the door, the door check
LED will turn off.
Control panel description