5.5. Ensure Vehicle Ignition Key is off and turn Battery Disconnect off so that the
Battery Pack is completely disconnected from Vehicle and loads. If a disconnect
switch is not available, disconnect Positive and Negative Cables from Battery
Pack. Confirm disconnection by checking with a voltmeter from frame to
positive and negative battery terminals. If not familiar with the use of
voltmeters: STOP Installation, and refer service to a Qualified Electrical
Technician.
5.6. Using a Voltmeter and Ohm-meter, check and verify all wiring connections in
accordance with Wiring Diagram Drawing used.
WARNING:
On cables constructed to run from Battery Positive (+) Terminal to the
Converter Positive (+) input, a Waterproof Automotive Grade in-line Fuse
holder must be installed within 6inches (15cm) from Battery Positive (+)
Terminal. On the cable constructed to run from the Converters High
Output Positive (+) terminal to the electrical load(s), install a Waterproof
and Automotive Grade in-line Fuse holder and place this fuse holder within
6inches (15cm) of the Converter Terminals Positive (+) output. For every
output circuit originating from the output of the Converter, the installer
must ensure that EACH CIRCUIT is fitted with its own Fuse where the
fuse is properly rated to protect the load that it services.
WARNING:
Holder Connect terminals must be BOTH crimped and
soldered to assure mechanical AND electrical bondage. 30 amp
currents are Welding Current Levels and improper
connections may result in heat points, fire and/or permanent
equipment / property damage and/or worse: personal injury.
CAUTION:
shorts, and wiring to wiring shorts. Also check all nut and bolt
fasteners (if any used) for tightness of connections and ensure
that these connections have been properly protected from
environmental exposure with the use of grease or similar
materials. Check and Confirm polarity of output wiring prior
to making any connections to electrical loads.
5.7. Ensure all electrical loads are disconnected from Converter's output. Enable
Battery Pack Disconnect Switch and/or reconnect Battery cables back to Battery
Pack Terminals to apply power to the converter.
PROPER FUSING MUST BE INSTALLED BY USER.
Wire connections to Connector Pins and Fuse
Using Ohm Meter, check for wiring to chassis
5