Переглянути онлайн або завантажити pdf Довідковий посібник для Контролер AMS Controls MP328CL. AMS Controls MP328CL 17 сторінок. Closed loop backgauge controller
MP328CL Switch Settings
MP328CL Inputs/Outputs
AMS Controls
5/23/2012
Switch
1
2
3
4
5
6
7
The proper Unit ID switch setting for the MP328CL is: switches 2
and 3 ON.
Some systems have the capability of having 2
MP328CLs, and the Unit ID switch setting for the second
controller is: switches 1, 2, and 3 ON.
Inputs
1
2
3
4
5
6
7
8
Outputs
1
2
3
4
5
6
7
8
Pin 14
Pin 15
16
Description
Unit ID Must be OFF
Unit ID Must be ON
Unit ID Must be ON
Analog Polarity
Encoder Direction
Not Used Must be OFF
Unit ID Must be OFF
Description
Jog Forward
Jog Reverse
Home
Run Enable
Setup/Lockout
E-Stop
Sheet Detect
Loop Enable
Description
Drive Enable
Not Used
Not Used
Run
No Brake
Not Used
Gripper
Brake
Analog +
Analog -
MP328CL Controller
Gripper