The Open Period begins timing after the completion of the Delay Period, and is indicated by a repeating 4 beeps
o
and LED flashes every five seconds.
During the Open Period, the User must key a valid combination to cause the lock to open.
o
The Open Period can be set for 1 to 9 minutes long. (F03)
o
Time Delay can be canceled during the delay period by pressing "C – (any number key) - #".
o
Armored Car Time Delay Bypass - This feature allows the Time Delay to be used under normal access situations,
but provides a means to bypass time delay when cash handling methods require that an Armored Car courier can take
deposits without waiting for the delayed access.
This feature must be Enabled (F40).
o
It still requires that a valid resident User be present to open the safe.
o
The Armored Car Code (User 9) can be keyed in first, followed by a valid User code or, the Armored Car Code
o
can be used during the Delay Period to stop the delay, then the local User can open the lock with a valid code.
The Armored Car Bypass can be restricted to use by only the Manager User. (F41)
o
Multiple Users - Many cash handling protocols require that several people have access to the safe. The ESL20XL
provides several tools to manage a Multi-User environment. These controls are uniquely tailored to support retail loss
prevention.
This feature must be Enabled (F10).
o
The Master User, or Manager, is the only User with Administration capabilities.
o
In Multi-User mode, there is no need for all Users to share the same combination, as is the case with a
o
mechanical combination lock.
This feature allows the supervisor the ability to control the subordinate Users individually and makes employee
o
turnover easier to manage because individual Users can be added and deleted at will without affecting others.
The ESL20XL allows up to eight (8) subordinate Users to be enrolled.
o
A "Poor Man's Time Lock" effect can be implemented daily where the Master User can disable the Multi-User
o
Mode (F13) at the end of the day and then re-enable the mode at the beginning of the next business day. This
causes the lock to reject all the Subordinate User Codes during off-business hours. The individual subordinate
User codes are not lost, just disabled.
Subordinate User Control - The Master User has the option of allowing, or not allowing, certain capabilities of the
Subordinate Users as follows.
The Subordinate User changing their own combination. (F60)
o
Two Subordinate Users opening the safe in Dual Combo Mode. (F31)
o
The Subordinate User authorizing Armored Car Time Delay Bypass. (F41)
o
Dual Control - This feature provides a higher level of security, where two different combinations are required to open
the safe.
This feature must be Enabled (F30).
o
When Dual Control is Enabled, the lock requires two Users key their individual combinations, one after the
o
other, before the lock will open.
The second User has 10 seconds to start code entry before the system discards the login and goes to sleep.
o
Revision A
ESL20XL Operating Instructions
Page 3 of 10
Released Aug. 9, 2018