Do not install the unit near a source of heat, steam, or fl ammable gas.
Install the unit where drainage does not cause any trouble.
Install the indoor unit, power supply cable, transmission cable, and remote controller
cable at least 1 m away from a television or radio receivers. The purpose of this is to
prevent TV reception interference or radio noise. (Even if they are installed more than
1 m apart, you could still receive noise under some signal conditions.)
If children under 10 years old may approach the unit, take preventive measures so
that they cannot reach the unit.
Take precautions to prevent the unit from falling.
(1) Install the indoor unit on a place having a sufficient strength so that it withstands
against the weight of the indoor unit.
(2) The inlet and outlet ports should not be obstructed; the air should be able to blow all
over the room.
(3) Leave the space required to service the air conditioner.
(4) Install the unit where connection to the outdoor unit (or RB unit) is easy.
(5) Install the unit where the connection pipe can be easily installed.
(6) Install the unit where the drain pipe can be easily installed.
(7) Install the unit where noise and vibrations are not amplifi ed.
(8) Take servicing, etc., into consideration and leave the spaces. Also install the unit
where the fi lter can be removed.
(9) Do not install the unit where it will be exposed to direct sunlight.
3.2. Installation dimension
Floor console
Left
300 or
more
Under ceiling
Left
150 or
more
3.3. Installing the unit
Install the air conditioner in a location which can withstand a load of at least 5 times
the weight of the main unit and which will not amplify sound or vibration. If the
installation location is not strong enough, the indoor unit may fall and cause injuries.
En-3
CAUTION
Right
Unit : mm
300 or
more
Ceiling
Right
Indoor unit
300 or
more
Ceiling
2300 or
20 or more
more
Floor
Unit : mm
WARNING
3.3.1. Preparing indoor unit installation
Open the intake grille and remove the 3 screws.
Tapping screw
Intake grille
Remark : The main unit can be wired before the indoor unit is installed.
Select the most appropriate installation order.
3.3.2. Indoor unit installation
A. Floor console type
Drilling for piping
Select piping and drain directions.
The piping and drain can be made in 3 directions as shown below.
For direction, bore the oval hole shown in the above fi gure.
The drain hose can be connected to either the left or right side.
Drain hose
(Left side)
When the directions are selected, drill a 10 cm dia. hole on the wall so that the hole is
tilted downward toward the outdoor for smooth water fl ow.
When the pipe is led out from the rear, make a hole as shown in the fi gure, at the position
shown.
Wall
100
Indoor side
When installing set to wall install the accessory wall bracket at the position as shown in
the fi gure, and mount the set to it.
990
500
65
Φ50
125
B. Under ceiling type
Using the installation template, drill holes for piping and suspension bolts (for holes).
900
Installation
template
200
(Accessories)
Drilling position for piping
Machine screw
Tapping screw
Hole
VIEW
Drain hose
(Right side)
6
Outdoor side
Unit : mm
245
Wall bracket
Side of set
Φ100
Unit : mm
100
Drilling position
for suspension
bolt
Ceiling
Wall
Unit : mm