Dragon-RC Speedo DX-10 WP45 Інструкція з експлуатації - Сторінка 4

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Контролер Dragon-RC Speedo DX-10 WP45. Dragon-RC Speedo DX-10 WP45 8 сторінок.

Programmable items and default settings
Settings below can only be changed by using the optional program card or pc link.
Default settings are shown in the orange boxes
programmable
Items
Cut-off Voltage
Running Mode
Motor timing
Initial Acceleration
Throttle Percent
Reverse
Throttle Limit
Percentage Braking
Percentage
Drag Brake
Motor Rotation
Neutral Range

1. Cutoff Voltage

Automatically detect the number of the cells
l
According to the type of your batteries , set up the type of the batteries and Low Voltage
Cutoff Threshold via PC software or program card. The ESC can detect the Voltage of
the battery anytime and will lower the power output once the Voltage of the battery is
lower than the preset Low Voltage Cutoff Threshold.
When using NiMH or NiCd batteries you do not need to set a cutoff voltage to
l
protect the batteries. If you are using more than 6-cell NiMH or NiCd batteries, you
must adjust the cutoff voltage, for example if you are using an 8-cell pack of NiMH
batteries you would use a cutoff of 5.6V volts (8 x 0.7V = 5.6V). When the voltage of
the batteries packs is within 8.4~12.6V, the ESC will automatically identify 3S LiPos.
When the voltage of the batteries packs is less than 8.4V, the ESC will automatically
identify 2S LiPos.
Customized Voltage Cutoff (for NiMH or NiCd Batteries) you can select a starting
l
cutoff voltage of 4, 5, 6, 9 or 12 volts. Then using the up/down to the right of the
voltage you can increase the voltage stepping up 0.1V between the selectable settings.
When using any Lithium batteries, they must not be discharged to less
l
than 3.0V per cell.
4
1
2
2.6V/cell
2.8V/cell
3.0V/cell 3.2V/cell 3.4V/cell No cut-off
Forward Forward with Forward/
w/o Reverse pause then Reverse
Reverse
Very Low
Low
Normal
Low
Medium
20%
30%
0%
20%
10%
20%
0%
4%
Normal
Reverse
2%
3%
Programmable Value
3
4
5
High
Very High
High
Very High
40%
50%
60%
30%
40%
50%
30%
40%
50%
8%
12%
15%
4%
5%
6%
6
7
8
9
70%
80% 90% 100%
60%
70% 80%
90%
60%
70% 80% 100%
20%
25% 30%
10%