Drain Master CE50 Посібник користувача - Сторінка 8
Переглянути онлайн або завантажити pdf Посібник користувача для Очищувачі для труб Drain Master CE50. Drain Master CE50 15 сторінок. Electric drain cleaner
Electric Drain Cleaner - CE50
•
To prevent cable whip, place the machine within 0.75m (2') of drain line or thread the cable through a
guide (not included). The greater the distance from the drain access, the higher the risk of cable whip,
twisting or kinking. If the machine cannot be placed close to the drain access, use appropriate-sized
pipes and fittings to extend the drain access back to the machine.
•
If needed, set up barriers to keep bystanders away from the work area.
•
Select the correct cutting tool. Install the cutting tool to the end of the cable. Slide the base of the cutting
tool into the slot at the end of the cable, then firmly fasten them with the attachment screw.
•
Position the foot switch for easy accessibility. You must be able to hold and control the cable, operate
the foot switch, and reach the motor switch.
•
Confirm that the motor switch is in the "OFF" position.
•
Run the electrical cord along a clear path. With dry hands, connect the machine to a properly grounded
electrical outlet. Keep all connections dry and off the ground. If the electrical cord is not long enough, use
a grounded extension cord that is in good condition. Keep the connection off the ground to prevent it
from getting wet. Also verify that the extension cord is rated for outdoor use and has sufficient wire size
(16 AWG for up to 16m (50') length, 14 AWG for up to 30m (100') length. Undersized wires can
overheat, melting the insulation or causing an electrical hazard, fire or other damage. When using an
extension cord, the GFCI on the machine does not protect the extension cord. If the outlet is not GFCI
protected, use a plug-in type GFCI between the outlet and the extension cord. This will reduce the risk of
electric shock if there is a fault in the extension cord.
E&OE
© 2018 Drain Master
8