Draper Access FIT E Інструкція з монтажу та експлуатації - Сторінка 2
Переглянути онлайн або завантажити pdf Інструкція з монтажу та експлуатації для Проекційний екран Draper Access FIT E. Draper Access FIT E 8 сторінок. Electric projection screen 220v
Також для Draper Access FIT E: Інструкція з монтажу та експлуатації (8 сторінок)
Access FIT E and V 220V
Electric projection screen
Section 3 - Bottom Access Fit Panel Installation/Removal
Bottom Access Panel Door
Caution: Beware of pinch points at ends of closure
Caution: For larger sizes, the following requires two people to perform safely.
1. Press up on Access
Fit panel and pull
toward the front of
the screen housing to
disengage hinges and
remove Access Fit
panel.
Remove Screws
from both ends
of Screen Housing
Improper installation and use of Access Fit Projection Screen can result in serious injury or death. Primarily, injuries can occur if the unit falls
due to imprecise installation, mishandling of the unit during installation or installation on an insufficient wall or ceiling structure. Please use
extreme care.
1. Please read the following installation guidelines thoroughly and follow them
carefully. Failure to do so may cause product to fall or otherwise fail, and could
result in serious injury.
2. Installation and calibration of the unit should only be performed by an
authorized, qualified, and experienced professional. In particular, electrical work
and wiring [indicated in diagram by dashed lines] must be completed only by a
qualified professional electrician who has read this manual completely and is
familiar with the construction and operation of this equipment and the hazards
involved.
3. Do not affix the unit to walls or ceilings that have inadequate strength
to permanently hold the unit during use. It is the owner's and installer's
responsibility to confirm the wall or ceiling to which the unit attaches is sufficient
to permanently hold the weight and stress loads of the unit at all times.
Draper, Inc., is not responsible for improper installation, application, testing or
workmanship related to the product at place of installation.
4. It is the installer's responsibility to make sure appropriate fasteners are used for
mounting.
5. All hardware must be installed level. Unit must be level and square.
6. Never leave the area while operating the unit during installation, maintenance, or
normal operation, unless it is secure and safe.
7. Before testing or operation, carefully inspect the entire area and path (especially
underneath) of unit to be sure no persons or objects are in the area.
1. Look for any job site conditions that could interfere with installation or operation
of the system.
2. Read carefully and be sure to understand all installation instructions and all
related operations manuals. These instructions are intended to serve as a guide
for the installer and owner. They should be followed closely and combined with
the expertise of experienced qualified installers. Draper, Inc., is not responsible
for improper installation, application, testing or workmanship related to the
product at place of installation. Please retain all instructions for future use.
Bottom flange of
Access housing
Figure 3
Access Fit case as seen from below
Access
Panel Door
pivot on Hinges
Figure 4
Removing Access Fit Panel
WARNING
Before Beginning Installation
Bottom Access Fit panel secures to the screen housing
with two screws
(one on each
end), and held in the closed
position by engagement brackets with ball detents that
snap into case support brackets
(Fig.
2. To Remove/
Install Support
Brackets:
8. Turn off power and any nearby equipment or cables carrying electricity before
connecting switches, wires, controls, or electrical components.
9. Do not wire motors in parallel without written permission from Draper, Inc.
10. During testing or operation, carefully watch the surrounding area for any
potential safety concerns including nearby persons or objects.
11. After installation, the entire system, including all sensors, should be carefully
tested to ensure safe and normal operation. Extreme care should be taken
during testing to remain clear of moving parts to avoid possible injury.
12. Operation of unit should be performed only by authorized and qualified
personnel, who have been trained in its safe and effective operation and
understand its safety features.
13. The safety features of the unit should never be disabled, bypassed or
overridden. The system should not be operated until all safety features are
properly and completely installed, calibrated and tested.
14. Unit may need to comply with local, state or district rules and regulations, in
particular when installed in schools. All applicable rules and regulations should
be reviewed before installation and use.
15. Failure to precisely follow installation guidelines invalidates all warranties.
16. Custom products/installations may not be reflected in this manual. Call Draper,
Inc., if you have questions about the installation of custom products or any
questions about your installation.
3. Open cartons lengthwise.
4. Locate and lay out all pieces.
5. Inspect all boxes to make sure you have received the proper unit and parts.
Controls may be shipped separately, or in same carton as unit .
6. If you have any difficulties with installing, servicing or operating your unit , call
your dealer or Draper, Inc., (765) 987-7999.
page 2 of 7
3).
A
P
CCESS
ANEL
S
B
UPPORT
RACKET
A
TTACHING BRACKETS
Insert pin in top
1
slot and push up
Rotate bracket
2
clockwise to lock
bracket in place
E
B
NGAGEMENT
RACKET
B
D
WITH
ALL
ETENT
will snap into Access
Panel Support Bracket.