Installation location
d
WARNING
Do not install the dryer:
- outdoors
- in an environment with dripping
water,
- near flammable materials,
- in rooms which are at risk of
frost,
- in rooms which may contain
gas or other fuels,
- in cupboards with lockable
doors or in alcoves.
The installation room must be well
ventilated, otherwise the dryer will
operate below optimum
performance.
Do not operate the dryer at
temperatures above 104 F (40 C)
and below 41 F (5 C). Low
temperatures affect the automatic
program sequence and may
prolong the drying times.
The installation surface for the dryer
must be clean, level and firm. Do
not install the appliance on carpets!
Compensate for uneven floors with
the height adjustable feet.
Install the dryer and level side to
side and front to back. Use a
bubble level. Never remove the
height adjustable feet!
The size of the installation area
depends on the dimensions of the
dryer. Ensure that there is adequate
room for the swivel range of the
door!
d
Dimension
a
27.0" (686 mm)
b
31.8" (808 mm)
c
37.2" (945 mm)
d
19.7" (500 mm)/
angle
170 - 180°
If installing the dryer in a closet,
observe the minimum distances
according to the following table:
Minimum Installation Clearances
Sides
Top
Rear
Important information concerning
minimum distances:
-
Depending on the location of
the exhaust air connection, an
additional minimum distance of
5½ inch (14 cm) must be
provided on this side for
pipes/brackets (see page 9).
-
Distances above the indicated
minimum dimensions reduce
the risk of mold formation
behind the appliance.
-
Additional distances reduce
noise transmission.
-
Additional distances facilitate
Weight
installation and service.
125 lbs
-
If the dryer is installed in a small
(56 kg)
(56 k )
room, the doors of the room
with
ith
must be fitted with vents of a
packaging
packaging
specified minimum size.
143 lbs
(64 kg)
Closet
0" (O mm)
12" (3O5 mm)
0" (O mm)
The dryer door is delivered with
hinges on the right. If required, the
door hinges can be switched to the
left side.
If the door hinges are to be
changed over, please contact your
dealer or our customer
service team (see page 25)
7