Draper Access XL Інструкція з монтажу та експлуатації - Сторінка 4

Переглянути онлайн або завантажити pdf Інструкція з монтажу та експлуатації для Проекційний екран Draper Access XL. Draper Access XL 5 сторінок. Draper access xl electric projection screen
Також для Draper Access XL: Інструкція з експлуатації (8 сторінок), Інструкція з монтажу та експлуатації (5 сторінок)

Draper Access XL Інструкція з монтажу та експлуатації
Access XL 220 Volt Instructions by Draper
229mm
265
254
mm
mm
241mm
Typical Installation: Two outermost ceiling
mounting brackets (on the ends) must be
centered over the interior roller brackets (+/-
102mm). Two intermediate brackets should
be spaced evenly from the outermost ceiling
mounting brackets.
Wiring Diagrams—220V Motor
Please Note: Do not wire motors in parallel.
Single Station Control
CE Approved
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Control
switch
Dashed wiring
by installer
220v,
50 Hz.

Case Dimensions

Series E Case Length = Fabric width + 321mm
Evenly Spaced
197mm
25.4
mm
L
216mm
Series V-L=varies
Series E-L=160mm
Ceiling Mounting Bracket Locations and Configurations
Multiple Station Control
Junction box at
Not CE Approved
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Cap off with wire
nut & tape
Blue
Red
Black
Blue
Red
Black
Red
Blue
Black
Dashed wiring
by installer
220v, 50 Hz.
www.draperinc.com
Series V Case Length = Varies
Centered over roller bracket (+/-102mm)
Evenly Spaced
Alternate Installation: Two outermost ceiling mounting
brackets (on the ends) are centered over the inte-
rior roller brackets (+/-102mm), parallel to the case.
The two intermediate brackets should be placed in
the typical perpendicular configuration, and spaced
evenly from the outermost ceiling mounting brackets.
Wiring Diagrams—220V Motor
with Built-in Low Voltage Controller
Single Low Voltage Control
Dashed wiring
Data Cable
by electrician
Wall Switch,
RF or IR
Receiver,
or integrated
control system
To 220V Line
*These wiring diagrams are for Access XL screens with motor on audi-
ence left (standard), and fabric unrolling from the back of the roller
(standard).
(765) 987-7999
page 4 of 5
Evenly Spaced
Multiple Low Voltage Controls
Dashed wiring
by electrician
Data
Cables
Wall Switches,
RF or IR
Receivers,
or integrated
control systems
To 220V Line