Drawmer DA 6 Посібник оператора - Сторінка 3

Переглянути онлайн або завантажити pdf Посібник оператора для Підсилювач Drawmer DA 6. Drawmer DA 6 6 сторінок. Stereo distribution pre-amp
Також для Drawmer DA 6: Посібник оператора (12 сторінок)

Drawmer DA 6 Посібник оператора
INSTALLATION
The DA6 is designed for standard 19" rack mounting and occupies 1U of rack space. Avoid
mounting the unit directly above power amplifiers or power supplies that radiate significant
amounts of heat. Always connect the mains earth to the unit. Use fibre or plastic washers to
prevent the front panel becoming marked by the mounting bolts.
AUDIO CONNECTIONS
Input and Output audio connections are provided via balanced XLRs at a level of +4dBu. This
applies to both inputs and outputs. The wiring convention being: Pin 1 Ground; pin 2 Hot; and
pin 3 Cold. For use with unbalanced systems, the Cold pin 3 must be grounded at both input
and output inside the XLR connectors.
The Stereo Link Outputs are balanced 1/4" (TRS) jack sockets, where Tip connection is Hot;
Ring is Cold; and Sleeve is Ground. These connections are offered for chaining multiple DA6
units if there is a requirement for more than 6 stereo outputs.
INTERFERENCE
If the unit is to be used where it maybe exposed to high levels of disturbance such as found
close to a TV or radio transmitter, we suggest that the unit be operated using an optional wiring
of the balanced configuration. The screens of the signal cables should be connected to the
chassis connection on the XLR connector as opposed to connecting to pin1. The DA6 fully
conforms to the EMC standards.
GROUND LOOPS
If ground loop problems are encountered, never disconnect the mains earth, but instead, try
disconnecting the signal screen on one end of each of the cables connecting the outputs of the
MX40 to the patchbay. If such measures are necessary, balanced operation is recommended.
ISOLATION TRANSFORMERS
The DA6 has the capability of being isolated at its outputs using low impedance (600 )
balanced transformers. Each output can be individually isolated, and it is possible to have
mixed configurations where some outputs retain their default connection of electronically
balanced. Isolating transformers can be factory fitted, or alternatively, retro fitted by a Drawmer
appointed service agent, or a suitably qualified engineer. The isolating transformer is
manufactured by Beyer (Gmbh) and has a part reference TR/BV310-101-031. The part
reference from Drawmer stock is #6105. Any warranty will be void if isolating transformers are
fitted by non-approved methods, or, if unspecified transformers are fitted.
MONITOR HEADPHONES
For the purposes of monitoring each output, a stereo 1/4" (TRS) jack socket is offered on the
front panel. This having the standard wiring convention of Tip being Left; Ring being Right; and
Sleeve being common Ground. This output is capable of driving headphones with an
impedance between 8 and 600 . The amplifier has an output of approximately 1Watt. Caution is
required when operating at high output levels with low impedance headphones.
POWER CONNECTION
The DA6 unit will have been supplied with a power cable suitable for domestic power outlets in
3