Bosch Evolution HES7282U Інструкція з монтажу Посібник з монтажу - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Духовка. Bosch Evolution HES7282U. Bosch Evolution HES7282U 48 сторінок. Electric free-standing range
Installation
Before You Begin
Tools and Parts Needed
Additional Parts Needed For
Hard Wire Installations
Parts Included
Cabinet Requirements
English 2
Power Requirements and Electrical Grounding Instructions
•
Before installing, turn power OFF at the service panel. Lock service panel to
prevent power from being turned ON accidentally.
•
Know how to disconnect the power to the range at the circuit breaker or fuse
box in case of an emergency.Installation
•
50 Amp Power Supply Cord Kit (not necessary for Canadian installations)
•
Measuring Tape
•
Phillips Head Screwdriver
•
1-1/4" (31.8 mm) Wrench
•
Pencil
•
T-20 Torx Screwdriver
•
Screws (2) and Anchors (2) for Anti-Tip Bracket (Style will vary depending on
mounting surface)
•
Level
•
Drill and Drill Bit
•
Safety Gloves and Goggles
•
Tape (Optional)
•
Cloth or Cardboard (Optional - to Protect Floor)
•
Flexible Conduit (For Hard Wire Installation Only)
•
Torque Wrench (For Hard Wire Installation Only)
•
Note: Power Supply Cord Kit Not Necessary For Hard Wire Installations
•
Anti-Tip Bracket
•
Terminal Lugs (For Use With Hard Wire Installations) (not necessary for
Canadian installations)
This unit is designed for installation near adjacent walls and projecting surfaces
constructed of combustible materials. Allow a minimum of 30 inches (76.2 cm)
between cabinets where range is to be installed (0.47" (12 mm) clearance from
range sidewall to cabinet required in Canada).
30" (76.2 cm) Minimum
between cabinets
Cabinet Clearances
Figure 1: