7.4 Internal assignment input

• Both inputs are made as diode lines for optocouplers.
• To simplify the assignment of potential-free contacts the supply voltage was bridged to additional.
Lock
• max. input voltage 12 VDC
• medium current consumption ca. 10mA

7.4.1 Internal assignment output

• When operating in mixed mode with batteries, they are "divided" electronically by mixing diodes as soon as the motor
voltage is higher than the open-circuit voltage of the battery (9V) – unnecessary discharging is avoided.
• All outputs are made as changeover contacts of a relay.
• The base contact (com) leads to a solder contact for a row resistor i.e. for a direct evaluation within an alarm circle by a
burglar alarm system.
• When using the changer as switch, either solder a jumper at this place or use the asigned solder jumper.
• The marking of the solder jumpers are numbered like the corresponding output relays:
- J1 and R1 correspond to relay Q1
- J2 and R2 correspond to relay Q2
- J3 and R3 correspond to relay Q3
- J4 and R4 correspond to relay release switch (sabotage)

7.5 Activate/deactivate I/Os

• The in-/output functions have tob e activated in the software GatorSelect or the input unit with the according access rights
before using them.
Abbreviated dialling
*30*
*31*
8
Installation instruction GatorSignal Plus
Activate I/O
Deactivate I/O