Drayton miGenie Wish 2 T724R Посібник з монтажу - Сторінка 2
Переглянути онлайн або завантажити pdf Посібник з монтажу для Контролер Drayton miGenie Wish 2 T724R. Drayton miGenie Wish 2 T724R 2 сторінки.
Step 7: Connection Charts
miGenie Controller
Biflo system: Model T724R
Arrowed numbers relate to the junction box.
! IMPORTANT:
* Consult boiler handbook for details of pump
overrun wiring.
Always switch off the mains before removing
the miGenie Controller – and never fit it to a live
wall-plate!
Make the wiring connections, as above, for the
After wiring, clip on the unit and tighten the securing
appropriate system. For surface wiring, snap out the
screws. Check the mains input has a 3A fuse, and switch
cable entry strip on the bottom edge of the wall-plate.
on the mains.
miGenie controllers are double-insulated and need
no earth connection, but an earthing continuity (loop)
terminal is provided for convenience.
Step 8: Advanced Settings
Feature
Description
Advanced settings
! CAUTION! These settings should only be modified by a qualified person. They can influence the
safety and the proper functioning of the system
System settings
These are settings applicable to the system controller unit, global settings
for bound nodes and internet connection settings
Backlight
miGenie controller options are:
On with timeout, Always on, Always off
miGenie thermostat options are:
On with timeout, always off
Lock settings
Enable or disable the screen lock for the miGenie controller. To lock:
enter a 3 digit code for protection. To unlock: enter the 3 digit code
Product Information
View product details for devices in the system e.g. part number, firmware version, etc.
Signal strength
Informs about the current signal strength of the products connected to the system
Internet options
Sub-menu relating to the connection of an internet gateway – enables
a gateway to be added, replaced or removed with an indication of signal strength.
System reset
Will reset all settings to factory pre-sets
Zone settings
Customise each zone according to personal preferences
These are setting which will be applied to a connected thermostat
Select zone
Select the zone for the following actions
Rename zone
To rename an existing zone
Edit schedule
Update the schedule for the zone
Zone setup
Contains detailed zone setup values – see below for descriptions
Minimum
The minimum set temperature that can be set
temperature
for the zone
Maximum
The maximum set temperature that can be set
temperature
for the zone
Eco
Temperature used for energy saving events
temperature
e.g. during the night
Comfort
Temperature used for comfort events
temperature
e.g. during the day
Offset
Adjust the displayed temperature to personal needs
temperature
miGenie Controller
Twinzone system: Model T724R
miGenie Controller
3 Zone system: Model T744R
Factory Pre-Set
Feature
Description
Device manager
Add, replace or remove RF room thermostats
Signal strength
Displays the signal strength of the selected zone, if a miGenie thermostat is connected to the zone
Channel settings (within
Customise the application type and associated control settings for zones following this
Zone settings)
application type
On with timeout
Application type
Selecting the application type pre-configures
the available zone information
000
Master code 401
Control type
Select TPI or TP.
*Heating zones only
TPI = Use if the house usually reaches setpoint in ≤ 1 hour.
TP = Use if the house usually reaches setpoint in ≥ 1 hour.
Cycle rate (only when
Select 3 cph (cycles per hour), 6 cph or 12 cph
control type is TPI or TP)
Frost temperature
Disable frost protection or set between 3-10°C
Valve protection
The output will be activated for the specified time (in minutes). This
will happen weekly, related to the last action of the output. Select 0
to 10 minutes.
Heating, H Water, LivRoom
Add and Remove Devices
(NB: only required if adding a new thermostat. All items in the Wish 1, 2 & 3 packs are pre-bound)
To manually connect a miGenie thermostat, insert the batteries into the thermostat and wait for "Bind?" to be
5°C
displayed, press ( ) to select. You will also need to enter the binding process on the miGenie Controller, by entering
the Advanced Settings menu, then the Zone settings and select the Device manager option. In this screen select
30°C
the Add thermostat option to complete the binding process. To remove a miGenie Thermostat enter the Device
manager option in the miGenie controller using the same sequence detailed above. The option will now display
Remove Thermostat, select this option and the thermostat will be removed from the system.
16°C
To manually connect a miGenie gateway, press and hold the button on the rear of the gateway for more than 5
seconds, the LED will repeatedly flash red-yellow-green. You will also need to enter the binding process on the
21°C
miGenie Controller, by entering the Advanced Settings menu, then System settings, then Internet options. In this
screen select the Add gateway option to complete the binding process. To remove a miGenie Gateway enter the
0°C
Internet options menu in the miGenie controller using the same sequence detailed above. The menu will display
Remove gateway, select this option and the gateway will be removed from the system.
Step 8: Advanced Settings
→
From the Home screen, select
Settings, then Advanced settings
as shown.
→
Technical Data
→
miGenie controller
Factory Pre-Set
Power Supply
230V a.c. +10% -10% 50Hz
Pre-bound
Switch Rating
2 (1) A 230V a.c. each switch
Wiring
Fixed wiring only, to comply with
current IET regulations (BS7671)
Battery life
Zone 1: Heating:
Zone 2: Hot Water
Ambient Temperature
Zone 3: Heating
Operating:
Zone 4: Unused
Storage:
TPI
Ambient humidity
(non condensing)
Temperature Range
6 cph
Control Accuracy
Timing resolution
5°C
Temperature resolution
Ball Pressure Test
0 mins (Off)
Temperature
Pollution Degree
Energy Class
IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
Software Class
Software Version
Maximum Radiated Power
Display: blank; Time: always kept
Without Mains Power
Program times: always preserved
Rated Impulse Voltage
Radio Frequency
Radio Signal Range
30m typically. The range may be affected by the composition / density and the number
Mounting
Industry standard wall plate
Relevant EC Directives:
Applied Standards:
Hereby, Schneider Electric Controls UK LTD, declares that this miGenie Wireless Packs is in compliance with the
essential requirements and other relevant provisions of RED-DIRECTIVE 2014/53/EU. Declaration of conformity
can be downloaded on: www.draytoncontrols.co.uk
From here you can edit the assigned zones, rename them if required
and check the Signal strength.
Select a name from the list or
select 'Custom zone name' to
create a new zone name.
miGenie thermostat
miGenie gateway
2 X 1.5V IEC LR6(AA) alkaline
5V d.c. 1A USB Micro-B
batteries
N/A
No wiring required
N/A
2 years typical
N/A
0º to 45ºC (miGenie controller 3 / 4 channel 0º to 40ºC)
-20ºC to 55ºC
Operating 25% to 90%
Storage 15% to 95%
5 ºC - 30 ºC
N/A
<0.6ºC at 4º / hour
N/A
1 minute
N/A
0.5°C
N/A
75ºC
2
N/A
A
6712076
6712075
6712077
+11dBm (12.6mW)
N/A
2.5kV
N/A
868.3MHz (Bi-directional communication)
of walls between the miGenie products
Wall bracket or table stand
Table top
2014/53/EU RED Directive
2013/56/EU Battery Directive
2011/65/EU RoHS Directive
EN60730-1; EN60730-2-7; EN60730-2-9
EN 300 220-2; EN 301 489-3