(COMPATIBLE WITH STRONG ACIDS SUCH AS PTSA)
SPECIFICATIONS
Maximum air inlet pressure (both models):
Air requirements (operating pressure):
Air inlet connection port:
Maximum fluid pressure:
Fluid connection ports (2x):
Valve actuation speed (ON/OFF cycles):
Pressure Drop w/ 70 cP Test Fluid:
(Varies w/ material press. and viscosity)
WARNING
!
Some materials and catalysts are extremely dangerous.
Wear proper PPE during installation and maintenance.
Consult the material SDS sheet for specific
PPE requirements.
WARNING
!
Know your operating pressures! Use only Binks hoses and
fittings rated for the required operating pressures for use
with this product. See maximum air and fluid pressure for
each model listed in the specifications.
7 bar [105 psi]
4.8-6.9 bar [70-100 psi]
M5 x 0.8 (f)
69 bar [1000 psi]
1/4" NPT (f)
55 cycles/min
1 PSI press. drop @ 500 PSI and 200 cc/min
7 PSI press. drop @ 500 PSI and 1000 cc/min
43 PSI press. drop @ 500 PSI and 3800 cc/min